Back to Search Start Over

Optimization and analysis of a multi-functional heat pump system with air source and gray water source in cooling mode.

Authors :
Liu, Xiaoyu
Shen, Hui
Lau, Siu-Kit
Li, Haorong
Source :
Energy & Buildings. Aug2017, Vol. 149, p339-353. 15p.
Publication Year :
2017

Abstract

A multi-functional heat pump system has been proposed to effectively utilize waste heat and heat capacity in gray water for heating and cooling of residential buildings. Condenser heat recovery is integrated into the system. This system was tested in two environmental chambers that mimic the outdoor and indoor environments, respectively. In this paper, the investigation of the optimized system is focused on the system optimization and performance in cooling mode. The drawbacks of the initial prototype are analyzed and fixed. The system performance in the initial and optimized prototypes are compared and analyzed. At outdoor temperature 35 °C, compared to initial type, the COP of optimized prototype increases up to 20.07% for space cooling mode and up to 21.51% for space cooling with hot water supply mode. This system is tested and analyzed at space cooling mode, space cooling with hot water supply mode and hot water supply only mode. [ABSTRACT FROM AUTHOR]

Details

Language :
English
ISSN :
03787788
Volume :
149
Database :
Academic Search Index
Journal :
Energy & Buildings
Publication Type :
Academic Journal
Accession number :
124140706
Full Text :
https://doi.org/10.1016/j.enbuild.2017.05.056