Back to Search Start Over

AC Loss Comparison Between Multifilament and Nonstriated YBCO Coils Designed for HTS Propulsion Motors.

Authors :
Xing, Dong
Patel, Jay
Sun, Qixing
Liang, Fei
Yuan, Weijia
Zhang, Min
Zhu, Jiahui
Zhang, Guomin
Source :
IEEE Transactions on Applied Superconductivity. Jun2017 Part 2, Vol. 27 Issue 4, Part 2, p1-5. 5p.
Publication Year :
2017

Abstract

In this paper, the properties of current capacity and ac transport loss of striated high temperature superconductor (HTS) coil is compared with ordinary HTS coil by using both experimental and simulation methods. The measurements were carried out by transporting a sinusoidal varying current at 77 K, with an amplitude range of 10–50 A in frequency from 70 up to 300 Hz. Measurement facilities and methods are explained in more detail in the paper. The critical current of the 4-mm width multifilament coil made with four filaments at a spacing 0.03 mm was found to be lower than that of the nonstriated coil. The frequency dependent characteristics agreed well in both experimental and simulated results. Reducing ac loss of HTS is one enabling factor for widespread adoption of the technology, and therefore, understanding its characteristics is important and discussed in this paper. Future plans based on this preliminary work are the testing of multifilament tapes in an axial flux motor field environment. [ABSTRACT FROM PUBLISHER]

Details

Language :
English
ISSN :
10518223
Volume :
27
Issue :
4, Part 2
Database :
Academic Search Index
Journal :
IEEE Transactions on Applied Superconductivity
Publication Type :
Academic Journal
Accession number :
124147438
Full Text :
https://doi.org/10.1109/TASC.2017.2669156