Back to Search Start Over

Green and efficient sample preparation method for the determination of catalyst residues in margarine by ICP-MS.

Authors :
Hartwig, Carla Andrade
Pereira, Rodrigo Mendes
Novo, Diogo La Rosa
Oliveira, Dirce Taina Teixeira
Mesko, Marcia Foster
Source :
Talanta. Nov2017, Vol. 174, p394-400. 7p.
Publication Year :
2017

Abstract

Responding to the need for green and efficient methods to determine catalyst residues with suitable precision and accuracy in samples with high fat content, the present work evaluates a microwave-assisted ultraviolet digestion (MW-UV) system for margarines and subsequent determination of Ni, Pd and Pt using inductively coupled plasma mass spectrometry (ICP-MS). It was possible to digest up to 500 mg of margarine using only 10 mL of 4 mol L −1 HNO 3 with a digestion efficiency higher than 98%. This allowed the determination of catalyst residues using the ICP-MS and free of interferences. For this purpose, the following experimental parameters were evaluated: concentration of digestion solution, sample mass and microwave irradiation program. The residual carbon content was used as a parameter to evaluate the efficiency of digestion and to select the most suitable experimental conditions. The accuracy evaluation was performed by recovery tests using a standard solution and certified reference material, and recoveries ranging from 94% to 99% were obtained for all analytes. The limits of detection for Ni, Pd and Pt using the proposed method were 35.6, 0.264 and 0.302 ng g −1 , respectively. When compared to microwave-assisted digestion (MW-AD) in closed vessels using concentrated HNO 3 (used as a reference method for sample digestion), the proposed MW-UV could be considered an excellent alternative for the digestion of margarine, as this method requires only a diluted nitric acid solution for efficient digestion. In addition, MW-UV provides appropriate solutions for further ICP-MS determination with suitable precision (relative standard deviation < 7%) and accuracy for all evaluated analytes. The proposed method was applied to margarines from different brands produced in Brazil, and the concentration of catalyst residues was in agreement with the current legislation or recommendations. [ABSTRACT FROM AUTHOR]

Details

Language :
English
ISSN :
00399140
Volume :
174
Database :
Academic Search Index
Journal :
Talanta
Publication Type :
Academic Journal
Accession number :
124248511
Full Text :
https://doi.org/10.1016/j.talanta.2017.06.037