Back to Search Start Over

Energy and economic optimization of the repowering of coal-fired municipal district heating source by a gas turbine.

Authors :
Tańczuk, M.
Skorek, J.
Bargiel, P.
Source :
Energy Conversion & Management. Oct2017, Vol. 149, p885-895. 11p.
Publication Year :
2017

Abstract

One of the possible solution for conventional coal-fired heat sources of district heating systems is repowering with a cogeneration of heat and power) unit. Thermal and economic optimization of the such modernization is the subject of the paper. The total capacity of the existing heat generating plant reaches 210 MW and the generated heat is delivered to the city consuming central heating and hot domestic water. The optimization of the cogeneration system (regarding unit size) was aimed at finding a solution which is an optimal in terms of the economic efficiency. The optimal size of gas turbine was found and it has been proven that the retrofitting coal-fired district heating source with a gas turbine cogeneration unit has technical and economic justification and always leads to the energetic and ecological effects. However, the optimal size of the unit is highly sensitive to electricity and natural gas prices. [ABSTRACT FROM AUTHOR]

Details

Language :
English
ISSN :
01968904
Volume :
149
Database :
Academic Search Index
Journal :
Energy Conversion & Management
Publication Type :
Academic Journal
Accession number :
124796087
Full Text :
https://doi.org/10.1016/j.enconman.2017.03.053