Experimental approach to measure thick target neutron yields induced by heavy ions for shielding.
- Source :
-
EPJ Web of Conferences . 2017, Vol. 153, p1-4. 4p. - Publication Year :
- 2017
-
Abstract
- Double differential (angular and energy) neutron distributions were measured using an activation foil technique. Reactions were induced by impinging two low-energy heavy-ion beams accelerated with the GANIL CSS1 cyclotron: (36S (12 MeV/u) and 208Pb (6.25 MeV/u)) onto thick natCu targets. Results have been compared to Monte-Carlo calculations from two codes (PHITS and FLUKA) for the purpose of benchmarking radiation protection and shielding requirements. This comparison suggests a disagreement between calculations and experiment, particularly for high-energy neutrons. [ABSTRACT FROM AUTHOR]