Back to Search Start Over

Development of breath test for pneumoconiosis: a case-control study.

Authors :
Hsiao-Yu Yang
Ruei-Hao Shie
Che-Jui Chang
Pau-Chung Chen
Yang, Hsiao-Yu
Shie, Ruei-Hao
Chang, Che-Jui
Chen, Pau-Chung
Source :
Respiratory Research. 10/17/2017, Vol. 18, p1-8. 8p. 2 Charts, 2 Graphs.
Publication Year :
2017

Abstract

<bold>Background: </bold>Lipid peroxidation plays an important role in the pathogenesis of pneumoconiosis. Volatile organic compounds (VOCs) generated from lipid peroxidation might be used to detect pneumoconiosis. The objective of this study was to develop a breath test for pneumoconiosis.<bold>Methods: </bold>A case-control study was designed. Breath and ambient air were analysed by gas chromatography/mass spectrometry. After blank correction to prevent contamination from ambient air, we used canonical discriminant analysis (CDA) to assess the discrimination accuracy and principal component analysis (PCA) to generate a prediction score. The prediction accuracy was calculated and validated using the International Classification of Radiographs of the Pneumoconiosis criteria combined with an abnormal pulmonary function test as a reference standard. We generated a receiver operator characteristic (ROC) curve and calculated the area under the ROC curve (AUC) to estimate the screening accuracy of the breath test.<bold>Results: </bold>We enrolled 200 stone workers. After excluding 5 subjects with asthma and 16 subjects who took steroids or nonsteroidal anti-inflammatory drugs, a total of 179 subjects were used in the final analyses, which included 25 cases and 154 controls. By CDA, 88.8% of subjects were correctly discriminated by their exposure status and the presence of pneumoconiosis. After excluding the VOCs of automobile exhaust and cigarette smoking, pentane and C5-C7 methylated alkanes constituted the major VOCs in the breath of persons with pneumoconiosis. Using the prediction score generated from PCA, the ROC-AUC was 0.88 (95% CI = 0.80-0.95), and the mean ROC-AUC of 5-fold cross-validation was 0.90. The breath test had good accuracy for pneumoconiosis diagnosis.<bold>Conclusion: </bold>The analysis of breath VOCs has potential in the screening of pneumoconiosis for its non-invasiveness and high accuracy. We suggest that a multi-centre study is warranted and that all procedures must be standardized before clinical application. [ABSTRACT FROM AUTHOR]

Details

Language :
English
ISSN :
14659921
Volume :
18
Database :
Academic Search Index
Journal :
Respiratory Research
Publication Type :
Academic Journal
Accession number :
125748024
Full Text :
https://doi.org/10.1186/s12931-017-0661-3