Back to Search Start Over

Assessing lung function using contrast-enhanced dual-energy computed tomography for potential applications in radiation therapy.

Authors :
Lapointe, Andréanne
Bahig, Houda
Blais, Danis
Bouchard, Hugo
Filion, Édith
Carrier, Jean ‐ François
Bedwani, Stéphane
Source :
Medical Physics. Oct2017, Vol. 44 Issue 10, p5260-5269. 10p. 2 Color Photographs, 1 Black and White Photograph, 1 Chart, 2 Graphs.
Publication Year :
2017

Abstract

Purpose: There is an increasing interest in the evaluation of lung function from physiological images in radiation therapy treatment planning to reduce the extent of postradiation toxicities. The purpose of this work was to retrieve reliable functional information from contrast-enhanced dualenergy computed tomography (DECT) for new applications in radiation therapy. The functional information obtained by DECT is also compared with other methods using single-energy CT (SECT) and single-photon emission computed tomography (SPECT) with CT. The differential function between left and right lung, as well as between lobes is computed for all methods. Methods: Five lung cancer patients were retrospectively selected for this study; each underwent a SPECT/CT scan and a contrast-injected DECT scan, using 100 and 140 Sn kVp. The DECT images are postprocessed into iodine concentration maps, which are further used to determine the perfused blood volume. These maps are calculated in two steps: (a) a DECT stoichiometric calibration adapted to the presence of iodine and followed by (b) a two-material decomposition technique. The functional information from SECT is assumed proportional to the HU numbers from a mixed CT image. The functional data from SPECT/CT are considered proportional to the number of counts. A radiation oncologist segmented the entire lung volume into five lobes on both mixed CT images and low-dose CT images from SPECT/CT to allow a regional comparison. The differential function for each subvolume is computed relative to the entire lung volume. Results: The differential function per lobe derived from SPECT/CT correlates strongly with DECT (Pearson’s coefficient r = 0.91) and moderately with SECT (r = 0.46). The differential function for the left lung shows a mean difference of 7% between SPECT/CT and DECT; and 17% between SPECT/CT and SECT. The presence of nonfunctional areas, such as localized emphysema or a lung tumor, is reflected by an intensity drop in the iodine concentration maps. Functional dose volume histograms (fDVH) are also generated for two patients as a proof of concept. Conclusion: The extraction of iodine concentration maps from a contrast-enhanced DECT scan is achieved to compute the differential function for each lung subvolume and good agreement is found in respect to SPECT/CT. One promising avenue in radiation therapy is to include such functional information during treatment planning dose optimization to spare functional lung tissues. [ABSTRACT FROM AUTHOR]

Details

Language :
English
ISSN :
00942405
Volume :
44
Issue :
10
Database :
Academic Search Index
Journal :
Medical Physics
Publication Type :
Academic Journal
Accession number :
126270276
Full Text :
https://doi.org/10.1002/mp.12475