Underrecognized entity of the transient rise in the atrial capture threshold early after dual-chamber pacemaker implantation.

Authors :
Uehara, Yoshiko
Yoshida, Kentaro
Kimata, Akira
Ogawa, Kojiro
Abe, Daisuke
Tsumagari, Yasuaki
Tsuneoka, Hidekazu
Yui, Yoshiaki
Ito, Yoko
Ebine, Mari
Takeyasu, Noriyuki
Aonuma, Kazutaka
Nogami, Akihiko
Source :
Pacing & Clinical Electrophysiology. Dec2017, Vol. 40 Issue 12, p1396-1404. 9p.
Publication Year :
2017

Abstract

Background Steroid-eluting pacemaker leads suppress acute rises in pacing threshold by preventing inflammatory processes. However, we occasionally encounter not persistent but transient rise in the atrial capture threshold (TRACT) early after pacemaker implantation. We believe that this phenomenon is underrecognized in clinical practice and may potentially lead to unnecessary reintervention. We aimed to clarify the prevalence, predictors, and possible mechanisms of TRACT. Methods and results We reviewed clinical records from 239 consecutive patients who underwent dual-chamber pacemaker implantation for sick sinus syndrome (SSS) (N = 102) or atrioventricular block (AVB) (N = 137). Atrial capture threshold was measured at implantation and 7 days, 2 months, and 8 months postimplantation. TRACT was defined as a rise in the threshold at day 7 to ≥twice that at implantation, with an absolute value ≥1.0 V/0.4 ms, and full recovery by 8 months into follow-up. TRACT was observed in 15 patients (6%), of whom13 (87%) suffered from SSS but not AVB. Patients with TRACT had greater body mass index (BMI) (25 ± 5 kg/m2 vs 23 ± 4 kg/m2, P = 0.01), larger left atrium (42 ± 5 mm vs 38 ± 7 mm, P = 0.03), and were more likely to suffer from paroxysmal atrial fibrillation (60% vs 31%, P = 0.02) than those without TRACT. In multivariable logistic regression analysis, BMI and SSS were the independent predictors of TRACT (odds ratio [OR], 1.172; 95% confidence interval [CI], 1.019-1.349; P = 0.03 and OR, 11.53; 95% CI, 2.010-66.21; P = 0.006, respectively). Conclusions The distinct phenomenon of TRACT was not rare in clinical practice early after dual-chamber pacemaker implantation, and its occurrence was strongly associated with SSS. [ABSTRACT FROM AUTHOR]

Details

Language :
English
ISSN :
01478389
Volume :
40
Issue :
12
Database :
Academic Search Index
Journal :
Pacing & Clinical Electrophysiology
Publication Type :
Academic Journal
Accession number :
126818467
Full Text :
https://doi.org/10.1111/pace.13235