Back to Search Start Over

A voltage unbalance factor coding technique for three‐phase induction motors.

Authors :
Abu‐Elhaija, Wejdan
Muetze, Annette
Source :
International Transactions on Electrical Energy Systems. Jun2018, Vol. 28 Issue 6, p1-1. 16p.
Publication Year :
2018

Abstract

Summary: This work investigates the effect of voltage unbalance on the starting and steady‐state performances of squirrel cage induction motors. Emphasis is placed on the rotor flux and slip. Both copper losses accumulated during the run up and at steady state are investigated. Five motor ratings of up to 4000 kVA operating at partial and at full load are studied. Because the same voltage unbalance factor may result in different behaviors, a voltage code is proposed to simplify referring to the individual per unit phase magnitudes. Full load operation at a voltage unbalance factor higher than 3.5% showed an increase of copper losses of more than 50%. Voltage unbalance cases that fail to pull up the motor to at least 50% of the rated speed show rotor fluxes too low to generate the required torque. [ABSTRACT FROM AUTHOR]

Subjects

Subjects :
*INDUCTION motors
*COPPER

Details

Language :
English
ISSN :
20507038
Volume :
28
Issue :
6
Database :
Academic Search Index
Journal :
International Transactions on Electrical Energy Systems
Publication Type :
Academic Journal
Accession number :
130267190
Full Text :