Back to Search Start Over

Predictive Analysis of the Damage to Axial-Flow Pump's Impeller in Sandy Water.

Authors :
Hua HONG
Zhang ZHI-ZHONG
Liu XIAO-BING
Zeng YONG-ZHONG
Wang HUI-YAN
Source :
Mechanika. 2018, Vol. 24 Issue 3, p323-328. 6p. 1 Diagram, 2 Charts, 13 Graphs.
Publication Year :
2018

Abstract

With the use of RNG k-ε turbulence model, SIMPLEC algorithm and CFD software, the turbulent flow in an axial flow impeller was numerically simulated in the clear water (single-phase) and the sandy water (solid-liquid twophase) conditions. The distributions of solid concentration, velocity and pressure on the impeller of an axial flow pump were analyzed at the same particle diameter but different volume concentrations in sandy water. And these distributions were comparatively analyzed under the clear water and the sandy water conditions. According to the simulation results, the axial pump impeller will be damaged more easily and quickly in sandy water than in clear water. And the area more prone to damage on the axial flow impeller is predicated. The predicted vulnerable parts in an axial flow impeller are consistent with that in actual projects. This study shows that the numerical simulation results are the same as the actual situation, and it has guiding significance for the wear design of the axial flow pump. [ABSTRACT FROM AUTHOR]

Details

Language :
English
ISSN :
13921207
Volume :
24
Issue :
3
Database :
Academic Search Index
Journal :
Mechanika
Publication Type :
Academic Journal
Accession number :
130523511
Full Text :
https://doi.org/10.5755/j01.mech.24.3.13854