Back to Search Start Over

Bioelectrocatalytic and electrochemical cascade for phosphate sensing with up to 6 electrons per analyte molecule.

Authors :
Kopiec, Gabriel
Starzec, Karolina
Kochana, Jolanta
Kinnunen-Skidmore, Troy P.
Schuhmann, Wolfgang
Campbell, Wilbur H.
Ruff, Adrian
Plumeré, Nicolas
Source :
Biosensors & Bioelectronics. Oct2018, Vol. 117, p501-507. 7p.
Publication Year :
2018

Abstract

Despite the availability of numerous electroanalytical methods for phosphate quantification, practical implementation in point-of-use sensing remains virtually nonexistent because of interferences from sample matrices or from atmospheric O 2 . In this work, phosphate determination is achieved by the purine nucleoside phosphorylase (PNP) catalyzed reaction of inosine and phosphate to produce hypoxanthine which is subsequently oxidized by xanthine oxidase (XOx), first to xanthine and then to uric acid. Both PNP and XOx are integrated in a redox active Os-complex modified polymer, which not only acts as supporting matrix for the bienzymatic system but also shuttles electrons from the hypoxanthine oxidation reaction to the electrode. The bienzymatic cascade in this second generation phosphate biosensor selectively delivers four electrons for each phosphate molecule present. We introduced an additional electrochemical process involving uric acid oxidation at the underlying electrode. This further enhances the anodic current (signal amplification) by two additional electrons per analyte molecule which mitigates the influence of electrochemical interferences from the sample matrix. Moreover, while the XOx catalyzed reaction is sensitive to O 2 , the uric acid production and therefore the delivery of electrons through the subsequent electrochemical process are independent of the presence of O 2 . Consequently, the electrochemical process counterbalances the O 2 interferences, especially at low phosphate concentrations. Importantly, the electrochemical uric acid oxidation specifically reports on phosphate concentration since it originates from the product of the bienzymatic reactions. These advantageous properties make this bioelectrochemical-electrochemical cascade particularly promising for point-of-use phosphate measurements. [ABSTRACT FROM AUTHOR]

Details

Language :
English
ISSN :
09565663
Volume :
117
Database :
Academic Search Index
Journal :
Biosensors & Bioelectronics
Publication Type :
Academic Journal
Accession number :
131071221
Full Text :
https://doi.org/10.1016/j.bios.2018.06.047