Back to Search Start Over

On the Switching Frequency of Hysteresis Control in a Silicon Carbide Converter Pump-Back Test.

Authors :
She, Xu
Frangieh, Tony
Datta, Rajib
Source :
IEEE Transactions on Industry Applications. Sep2018, Vol. 54 Issue 5, p4886-4893. 8p.
Publication Year :
2018

Abstract

The pump-back test is widely adopted in the industry for characterizing and qualifying high-power converters. One popular pump-back test configuration is to tie the dc links of two converters together and circulate the current through the inductor connected between the ac terminals. In this configuration, one of the converters operates in the voltage mode to generate the virtual grid and the other converter regulates the circulating current, where hysteresis control could be applied. However, the switching characteristics of hysteresis control are unique due to the pulsewidth modulation type voltage being the virtual grid. This paper contributes to analyzing the switching frequency characteristics of the hysteresis control in this pump-back test configuration. The switching frequency tracking phenomenon is revealed and reported in this paper for the first time. Theoretical analysis, simulation validation, and experimental demonstration are provided to support the major conclusions. [ABSTRACT FROM AUTHOR]

Details

Language :
English
ISSN :
00939994
Volume :
54
Issue :
5
Database :
Academic Search Index
Journal :
IEEE Transactions on Industry Applications
Publication Type :
Academic Journal
Accession number :
131880558
Full Text :
https://doi.org/10.1109/TIA.2018.2840080