Back to Search Start Over

Paper-based Vertical Flow Immunoassay (VFI) for detection of bio-threat pathogens.

Authors :
Chen, Peng
Gates-Hollingsworth, Marcellene
Pandit, Sujata
Park, Anson
Montgomery, Douglas
AuCoin, David
Gu, Jian
Zenhausern, Frederic
Source :
Talanta. Jan2019, Vol. 191, p81-88. 8p.
Publication Year :
2019

Abstract

Abstract Currently, the standard method for identifying biological agents of potential threats to national security and public health, such as pathogens, virus, and toxins, mainly rely on microbiological cultivation. This method is time-consuming and it requires sophisticated equipment and well-trained personnel, which are often unavailable in remote areas or at point-of-need. Therefore, an alternative rapid, simple, and sensitive method for detecting bio-threat agents is in crucial need. We report a paper-based Vertical Flow Immunoassay (VFI) device that can overcome these limitations. The VFI device utilizes a nanoporous nitrocellulose membrane encapsulated in a stainless steel filter holder. As the sample is pushed through the membrane, which is pre-functionalized with capture antibody, a sandwich assay is formed and colorimetric signal is generated to reflect the presence of target antigens. Through theoretical analyses of antigen-antibody binding process inside a porous membrane, we identified two critical factors – membrane pore size and sample flow rate that can be optimized to improve the assay sensitivity. Then, the effects were demonstrated through experimental studies using Burkholderia pseudomallei (the causative agent of melioidosis) as a model pathogen. The B. pseudomallei VFI was based on an immunoassay targeting the B. pseudomallei surface capsular polysaccharide (CPS). The experimental results agreed well with the theory showing that increasing the flow speed (up to 1.06 mm/s) and reducing the membrane pore size (down to 0.1 µm) could improve the sensitivity by at least 5 times. The VFI's limit-of-detection for CPS spiked in buffer solution was determined to be 0.02 ng/mL. The developed VFI shows great potential as a point-of-care tool for detection of bio-threat agents in a variety of clinical and resource-restricted conditions. Graphical abstract fx1 Highlights • Paper-based vertical flow device was developed to detect bio-threat pathogens. • Limit-of-detection for B. pseudomallei surface capsular polysaccharide was 0.02 ng/mL. • Sample flow rate and membrane pore size was studied in theory and experiment. • Multiplexing diagnostic of melioidosis and anthrax was demonstrated. [ABSTRACT FROM AUTHOR]

Details

Language :
English
ISSN :
00399140
Volume :
191
Database :
Academic Search Index
Journal :
Talanta
Publication Type :
Academic Journal
Accession number :
131947075
Full Text :
https://doi.org/10.1016/j.talanta.2018.08.043