Back to Search Start Over

Prevention of Arrhythmia Device Infection Trial: The PADIT Trial.

Authors :
Krahn, Andrew D
Longtin, Yves
Philippon, François
Birnie, David H
Manlucu, Jaimie
Angaran, Paul
Rinne, Claus
Coutu, Benoit
Low, R Aaron
Essebag, Vidal
Morillo, Carlos
Redfearn, Damian
Toal, Satish
Becker, Giuliano
Degrâce, Michel
Thibault, Bernard
Crystal, Eugene
Tung, Stanley
LeMaitre, John
Sultan, Omar
Source :
Journal of the American College of Cardiology (JACC). Dec2018, Vol. 72 Issue 24, p3098-3109. 12p.
Publication Year :
2018

Abstract

<bold>Background: </bold>Infection of implanted medical devices has catastrophic consequences. For cardiac rhythm devices, pre-procedural cefazolin is standard prophylaxis but does not protect against methicillin-resistant gram-positive organisms, which are common pathogens in device infections.<bold>Objective: </bold>This study tested the clinical effectiveness of incremental perioperative antibiotics to reduce device infection.<bold>Methods: </bold>The authors performed a cluster randomized crossover trial with 4 randomly assigned 6-month periods, during which centers used either conventional or incremental periprocedural antibiotics for all cardiac implantable electronic device procedures as standard procedure. Conventional treatment was pre-procedural cefazolin infusion. Incremental treatment was pre-procedural cefazolin plus vancomycin, intraprocedural bacitracin pocket wash, and 2-day post-procedural oral cephalexin. The primary outcome was 1-year hospitalization for device infection in the high-risk group, analyzed by hierarchical logistic regression modeling, adjusting for random cluster and cluster-period effects.<bold>Results: </bold>Device procedures were performed in 28 centers in 19,603 patients, of whom 12,842 were high risk. Infection occurred in 99 patients (1.03%) receiving conventional treatment, and in 78 (0.78%) receiving incremental treatment (odds ratio: 0.77; 95% confidence interval: 0.56 to 1.05; p = 0.10). In high-risk patients, hospitalization for infection occurred in 77 patients (1.23%) receiving conventional antibiotics and in 66 (1.01%) receiving incremental antibiotics (odds ratio: 0.82; 95% confidence interval: 0.59 to 1.15; p = 0.26). Subgroup analysis did not identify relevant patient or site characteristics with significant benefit from incremental therapy.<bold>Conclusions: </bold>The cluster crossover design efficiently tested clinical effectiveness of incremental antibiotics to reduce device infection. Device infection rates were low. The observed difference in infection rates was not statistically significant. (Prevention of Arrhythmia Device Infection Trial [PADIT Pilot] [PADIT]; NCT01002911). [ABSTRACT FROM AUTHOR]

Details

Language :
English
ISSN :
07351097
Volume :
72
Issue :
24
Database :
Academic Search Index
Journal :
Journal of the American College of Cardiology (JACC)
Publication Type :
Academic Journal
Accession number :
133642022
Full Text :
https://doi.org/10.1016/j.jacc.2018.09.068