Back to Search Start Over

An Improved Model Predictive Control Strategy to Reduce Common-Mode Voltage for Two-Level Voltage Source Inverters Considering Dead-Time Effects.

Authors :
Guo, Leilei
Jin, Nan
Gan, Chun
Xu, Lie
Wang, Qunjing
Source :
IEEE Transactions on Industrial Electronics. May2019, Vol. 66 Issue 5, p3561-3572. 12p.
Publication Year :
2019

Abstract

To reduce the common-mode voltage (CMV) and eliminate the CMV spikes for two-level voltage source inverters (2L-VSIs), an improved model predictive control (MPC) based CMV reduction method is proposed in this paper considering dead-time effects. First, an improved voltage vector (VV) preselection strategy is proposed to reduce the CMV spikes caused by the dead time. Second, a new hybrid VV preselection strategy based on a delay compensation strategy and a modified current sector division strategy is proposed to completely eliminate the CMV spikes. As the proposed hybrid VV preselection based MPC strategy makes full use of the six nonzero VVs of the 2L-VSI, the current total harmonic distortions and ripples are reduced. The simulation and experiments are carried out to verify the effectiveness of the proposed strategy. [ABSTRACT FROM AUTHOR]