Back to Search Start Over

Modelling electrical corrosion potential of 304 stainless steel under fusion power plant environment.

Authors :
Fang, Zhong
Tang, Jia
Xiao, Jiaxin
Tong, Lili
Cao, Xuewu
Weng, Hanqin
Lin, Mingzhang
Source :
Journal of Radioanalytical & Nuclear Chemistry. Jan2019, Vol. 319 Issue 1, p303-314. 12p. 1 Diagram, 3 Charts, 10 Graphs.
Publication Year :
2019

Abstract

Predicting the electrical corrosion potential (ECP) of type 304 stainless steel, the structural material of recirculation pipes in fusion power plants, is important because the growth rate of intergranular stress corrosion crack (IGSCC) of 304 stainless steel is closely related to ECP. In this work, a new model has been developed, by modifying existing models, to calculate the ECP of recirculation pipes in future fusion power plant. The calculation results indicate that merely injecting hydrogen cannot reduce ECP below EIGSCC if the dose rate exceeds a threshold, other assisted water chemistry controlling method is necessary. [ABSTRACT FROM AUTHOR]

Details

Language :
English
ISSN :
02365731
Volume :
319
Issue :
1
Database :
Academic Search Index
Journal :
Journal of Radioanalytical & Nuclear Chemistry
Publication Type :
Academic Journal
Accession number :
134585345
Full Text :
https://doi.org/10.1007/s10967-018-6299-x