Back to Search Start Over

In vivo confocal microscopy morphometric analysis of corneal subbasal nerve plexus in dry eye disease using newly developed fully automated system.

Authors :
Giannaccare, Giuseppe
Pellegrini, Marco
Sebastiani, Stefano
Moscardelli, Fabiana
Versura, Piera
Campos, Emilio C.
Source :
Graefe's Archive of Clinical & Experimental Ophthalmology. Mar2019, Vol. 257 Issue 3, p583-589. 7p.
Publication Year :
2019

Abstract

Purpose: To evaluate in vivo confocal microscopy (IVCM) features of corneal subbasal nerve plexus (SNP) in the setting of dry eye disease (DED) using fully automated software "ACCMetrics," and to further investigate its diagnostic performance in discriminating DED patients.Methods: IVCM exams of SNP in DED patients and matched control subjects were performed using Heidelberg Retina Tomograph with the Rostock Cornea Module. The following parameters were obtained with ACCMetrics: corneal nerve fiber density (CNFD), corneal nerve branch density (CNBD), corneal nerve fiber length (CNFL), corneal nerve total branch density (CTBD), corneal nerve fiber area (CNFA), corneal nerve fiber width (CNFW), and corneal nerve fractal dimension (CNFrD). The Mann-Whitney U test was used to compare variables. Receiver operating characteristic curves with calculations of the area under the curve (AUC) were used to describe the accuracy of IVCM parameters for discriminating DED patients from controls.Results: Thirty-nine DED patients and 30 control subjects were included. Significantly, lower values of CNFD, CNBD, and CNFL and higher value of CNFW were found in DED patients compared to controls (respectively, 20.5 ± 8.7 vs 25.4 ± 6.7 n/mm2; 25.6 ± 20.1 vs 37.6 ± 21.5 n/mm2; 12.6 ± 4.4 vs 14.5 ± 2.9 mm/mm2; 0.021 ± 0.001 vs 0.019 ± 0.001 mm/mm2; always p < 0.024). CNFW value had the highest diagnostic power in discriminating DED patients (AUC = 0.828). When the diagnosis of DED was made based on either CNFW or CNBD, the sensitivity was 97.4% and the specificity 46.7%.Conclusions: The software ACCMetrics was able to rapidly detect SNP alterations occurring in the setting of DED and showed good diagnostic performance in discriminating DED patients. [ABSTRACT FROM AUTHOR]

Details

Language :
English
ISSN :
0721832X
Volume :
257
Issue :
3
Database :
Academic Search Index
Journal :
Graefe's Archive of Clinical & Experimental Ophthalmology
Publication Type :
Academic Journal
Accession number :
134941558
Full Text :
https://doi.org/10.1007/s00417-018-04225-7