Back to Search Start Over

Lower plasma insulin levels during overnight closed-loop in school children with type 1 diabetes: Potential advantage? A randomized cross-over trial.

Authors :
Schierloh, Ulrike
Wilinska, Malgorzata E.
Pit-ten Cate, Ineke M.
Baumann, Petra
Hovorka, Roman
De Beaufort, Carine
null, null
Source :
PLoS ONE. 3/8/2019, Vol. 14 Issue 3, p1-11. 11p.
Publication Year :
2019

Abstract

Background: Studies have shown that overnight closed-loop insulin delivery can improve glucose control and reduce the risk of hypoglycemia and hence may improve metabolic outcomes and reduce burden for children with type 1 diabetes and their families. However, research so far has not reported insulin levels while comparing closed-loop to open-loop insulin delivery in children. Therefore, in this study we obtained glucose levels as well as plasma insulin levels in children with type 1 diabetes to evaluate the efficacy of a model—based closed-loop algorithm compared to an open-loop administration. Methods: Fifteen children with type 1 diabetes, 6–12 years, participated in this open-label single center study. We used a randomized cross over design in which we compared overnight closed-loop insulin delivery with sensor augmented pump therapy for two nights in both the hospital and at home (i.e., 1 night in-patient stay and at home per treatment condition). Only during the in-patient stay, hourly plasma insulin and blood glucose levels were assessed and are reported in this paper. Results: Results of paired sample t-tests revealed that although plasma insulin levels were significantly lower during the closed-loop than in the open-loop (Mean difference 36.51 pmol/l; t(13) = 2.13, p = .03, effect size d = 0.57), blood glucose levels did not vary between conditions (mean difference 0.76 mmol/l; t(13) = 1.24, p = .12, d = 0.37). The administered dose of insulin was significantly lower during the closed-loop compared with the open-loop (mean difference 0.10 UI; t(12) = 2.45, p = .02, d = 0.68). Conclusions: Lower insulin doses were delivered in the closed-loop, resulting in lower plasma insulin levels, whereby glucose levels were not affected negatively. This suggests that the closed-loop administration is better targeted and hence could be more effective. [ABSTRACT FROM AUTHOR]

Details

Language :
English
ISSN :
19326203
Volume :
14
Issue :
3
Database :
Academic Search Index
Journal :
PLoS ONE
Publication Type :
Academic Journal
Accession number :
135191925
Full Text :
https://doi.org/10.1371/journal.pone.0212013