Back to Search
Start Over
Rapid measurements of 235U fission product isotope ratios using an online, high-pressure ion chromatography inductively coupled plasma mass spectrometry protocol with comparison to isotopic depletion models.
- Source :
-
Journal of Radioanalytical & Nuclear Chemistry . Apr2019, Vol. 320 Issue 1, p153-163. 11p. 1 Diagram, 7 Charts, 8 Graphs. - Publication Year :
- 2019
-
Abstract
- An automated online separation-direct analysis method, RAPID (rapid analysis of post-irradiation debris), has been developed for the measurement of the concentration and isotopic composition of over 40 elements down to the low-picogram level. Here we discuss the application of RAPID to irradiated highly-enriched uranium, demonstrating that it has the sensitivity required to achieve precise, low-level analyses of non-natural isotopes, even in the presence of a bulk uranium matrix. Isotopic ratios have been successfully measured at the low-picogram level, and the accuracy of these ratios was confirmed using an isotopic depletion and decay modeling software to within 1-2%. [ABSTRACT FROM AUTHOR]
Details
- Language :
- English
- ISSN :
- 02365731
- Volume :
- 320
- Issue :
- 1
- Database :
- Academic Search Index
- Journal :
- Journal of Radioanalytical & Nuclear Chemistry
- Publication Type :
- Academic Journal
- Accession number :
- 135452293
- Full Text :
- https://doi.org/10.1007/s10967-019-06438-4