Interleaved Active Clamp Forward Converter With Extended Operating Duty Ratio by Adopting Additional Series-Connected Secondary Windings for Wide Input and High Current Output Applications.

Authors :
Youn, Han-Shin
Baek, Jae-Il
Kim, Jae-Kuk
Source :
IEEE Transactions on Power Electronics. May2018, Vol. 34 Issue 5, p4423-4433. 11p.
Publication Year :
2019

Abstract

This paper presents a new interleaved active clamp forward converter for low and wide input, and high current output applications. In the proposed converter, the operating duty ratio can be extended over 0.5 due to the additional powering path resulting from additional series-connected secondary windings from each transformer. As a result, the proposed converter can be designed with large transformer turns ratio. Thus, since the proposed converter can reduce not only the primary RMS current but also switch turn-off current, it can achieve high efficiency. Moreover, since all secondary switches can operate without floating gate drivers, the proposed converter can maintain simple structure and low complexity of gate driving circuits in the secondary side. The validity of this proposed converter is verified by the experimental results from 36V–72 V input and 12 V/500 W output for the dc/dc prototype. [ABSTRACT FROM AUTHOR]

Details

Language :
English
ISSN :
08858993
Volume :
34
Issue :
5
Database :
Academic Search Index
Journal :
IEEE Transactions on Power Electronics
Publication Type :
Academic Journal
Accession number :
135773628