Back to Search Start Over

Analytical Method to Estimate the Complex Permittivity of Oil Samples.

Authors :
Lijuan Su
Mata-Contreras, Javier
Vélez, Paris
Fernández-Prieto, Armando
Martín, Ferran
Source :
Sensors (14248220). Apr2018, Vol. 18 Issue 4, p984. 12p. 1 Color Photograph, 2 Diagrams, 2 Charts, 3 Graphs.
Publication Year :
2018

Abstract

In this paper, an analytical method to estimate the complex dielectric constant of liquids is presented. The method is based on the measurement of the transmission coefficient in an embedded microstrip line loaded with a complementary split ring resonator (CSRR), which is etched in the ground plane. From this response, the dielectric constant and loss tangent of the liquid under test (LUT) can be extracted, provided that the CSRR is surrounded by such LUT, and the liquid level extends beyond the region where the electromagnetic fields generated by the CSRR are present. For that purpose, a liquid container acting as a pool is added to the structure. The main advantage of this method, which is validated from the measurement of the complex dielectric constant of olive and castor oil, is that reference samples for calibration are not required. [ABSTRACT FROM AUTHOR]

Details

Language :
English
ISSN :
14248220
Volume :
18
Issue :
4
Database :
Academic Search Index
Journal :
Sensors (14248220)
Publication Type :
Academic Journal
Accession number :
135860633
Full Text :
https://doi.org/10.3390/s18040984