Back to Search Start Over

Laryngeal fractures treated with titanium mesh fixation.

Authors :
Sato, Taku
Nito, Takaharu
Ueha, Rumi
Goto, Takao
Yamasoba, Tatsuya
Source :
Auris Nasus Larynx. Jun2019, Vol. 46 Issue 3, p474-478. 5p.
Publication Year :
2019

Abstract

The larynx plays a vital role in respiration, swallowing, and vocal function. Thus, laryngeal fractures that are not appropriately managed may lead to permanent dyspnea, dysphagia, and voice disorders. In cases of laryngeal fractures, surgical repair by internal fixation has been performed with materials such as thread, steel wire, and titanium miniplates. However, thyroid and cricoid cartilage have a complicated morphology, and ossification at each site in the cartilage is not uniform; thus, in some cases it is difficult to perform internal fixation with conventional methods. In this case report, we describe two patients who underwent successful fixation of fractures in their laryngeal cartilage after trauma by using titanium mesh with thread and screws. Since optimal reduction and fixation of fractured laryngeal cartilage cannot be performed with conventional methods in patients with unossified cartilage, titanium mesh may be considered a safe and reliable alternative. [ABSTRACT FROM AUTHOR]

Details

Language :
English
ISSN :
03858146
Volume :
46
Issue :
3
Database :
Academic Search Index
Journal :
Auris Nasus Larynx
Publication Type :
Academic Journal
Accession number :
135994605
Full Text :
https://doi.org/10.1016/j.anl.2018.08.004