Back to Search Start Over

Interobserver reproducibility of tumor uptake quantification with 89Zr-immuno-PET: a multicenter analysis.

Authors :
Jauw, Yvonne W. S.
Bensch, Frederike
Brouwers, Adrienne H.
Hoekstra, Otto S.
Zijlstra, Josée M.
Pieplenbosch, Simone
Schröder, Carolien P.
Zweegman, Sonja
van Dongen, Guus A. M. S.
Menke-van der Houven van Oordt, C. Willemien
de Vries, Elisabeth G. E.
de Vet, Henrica C. W.
Boellaard, Ronald
Huisman, Marc C.
Source :
European Journal of Nuclear Medicine & Molecular Imaging. Aug2019, Vol. 46 Issue 9, p1840-1849. 10p. 2 Diagrams, 4 Charts, 1 Graph.
Publication Year :
2019

Abstract

Purpose: In-vivo quantification of tumor uptake of 89-zirconium (89Zr)-labelled monoclonal antibodies (mAbs) with PET provides a potential tool in strategies to optimize tumor targeting and therapeutic efficacy. A specific challenge for 89Zr-immuno-PET is low tumor contrast. This is expected to result in interobserver variation in tumor delineation. Therefore, the aim of this study was to determine interobserver reproducibility of tumor uptake measures by tumor delineation on 89Zr-immuno-PET scans. Methods: Data were obtained from previously published clinical studies performed with 89Zr-rituximab, 89Zr-cetuximab and 89Zr-trastuzumab. Tumor lesions on 89Zr-immuno-PET were identified as focal uptake exceeding local background by a nuclear medicine physician. Three observers independently manually delineated volumes of interest (VOI). Maximum, peak and mean standardized uptake values (SUVmax, SUVpeak and SUVmean) were used to quantify tumor uptake. Interobserver variability was expressed as the coefficient of variation (CoV). The performance of semi-automatic VOI delineation using 50% of background-corrected ACpeak was described. Results: In total, 103 VOI were delineated (3–6 days post injection (D3-D6)). Tumor uptake (median, interquartile range) was 9.2 (5.2–12.6), 6.9 (4.0–9.6) and 5.5 (3.3–7.8) for SUVmax, SUVpeak and SUVmean. Interobserver variability was 0% (0–12), 0% (0–2) and 7% (5–14), respectively (n = 103). The success rate of the semi-automatic method was 45%. Inclusion of background was the main reason for failure of semi-automatic VOI. Conclusions: This study shows that interobserver reproducibility of tumor uptake quantification on 89Zr-immuno-PET was excellent for SUVmax and SUVpeak using a standardized manual procedure for tumor segmentation. Semi-automatic delineation was not robust due to limited tumor contrast. [ABSTRACT FROM AUTHOR]

Details

Language :
English
ISSN :
16197070
Volume :
46
Issue :
9
Database :
Academic Search Index
Journal :
European Journal of Nuclear Medicine & Molecular Imaging
Publication Type :
Academic Journal
Accession number :
137453518
Full Text :
https://doi.org/10.1007/s00259-019-04377-6