Analysis of water consumption in toilets employing Shewhart, EWMA, and Shewhart-EWMA combined control charts.
- Source :
-
Journal of Cleaner Production . Oct2019, Vol. 233, p1146-1157. 12p. - Publication Year :
- 2019
-
Abstract
- The objective of this article is to statistically analyze and apply process control on water consumption in toilet flush devices in a public university building using Shewhart, EWMA and combined Shewhart-EWMA control charts. Data such as water volume, number of activations and flush-time duration were collected utilizing Smart-Meter sensors. A script was developed in R language to perform the appropriate statistical analysis, such as finding control charts control limits and transforming the obtained raw data into key variables: total volume per day, average flush volume, flush duration, and number of flushes per day. During the data gathering period, the regular single-flush equipment was replaced by a dual-flush model. The control charts Phase 1 is based on the collected data before the installation of the dual-flush devices, while Phase 2 is based on after replacement. After installing the new dual-flush devices, all control charts displayed visible changes based on the key variables. The replacement of the flush valves brought about a considerable reduction in water consumption in both male and female restrooms. There was a 21.72% reduction in average water consumption and a 12.09% average reduction in flushing time duration. The equipment replacement resulted in an evaluated Internal Rate of Return of 0.73%. Periodic monitoring of Shewhart Control Charts proved useful for observing large shifts of data, while EWMA control charts were more useful in locating small but constant data shifts. All chart models proved useful in identifying water consumption reduction and events such as leakages and water supply cutoffs occurring during the data gathering period. • The article goal is to analyze water consumption in toilet flush devices. • Shewhart, EWMA, and Combined Shewhart-EWMA control charts have been applied. • Dual-flush devices presented a reduction of 21% of water per flush. • Dual-flush devices reduced the flush duration by 12%. • All control charts proved useful for monitoring water consumption in toilets. [ABSTRACT FROM AUTHOR]
Details
- Language :
- English
- ISSN :
- 09596526
- Volume :
- 233
- Database :
- Academic Search Index
- Journal :
- Journal of Cleaner Production
- Publication Type :
- Academic Journal
- Accession number :
- 137475715
- Full Text :
- https://doi.org/10.1016/j.jclepro.2019.06.114