Back to Search Start Over

Human exposure to NO2 in school and office indoor environments.

Authors :
Salonen, Heidi
Salthammer, Tunga
Morawska, Lidia
Source :
Environment International. Sep2019, Vol. 130, p104887-104887. 1p.
Publication Year :
2019

Abstract

Although nitrogen dioxide (NO 2) is one of the most common air pollutants encountered indoors, and extensive literature has examined the link between NO 2 exposure and duration causing adverse respiratory effects in susceptible populations, information about global and local exposure to NO 2 in different indoor environments is limited. To synthesize the existing knowledge, this review analyzes the magnitude of and the trends in global and local exposure to NO 2 in schools and offices, and the factors that control exposure. For the literature review, Web of Science, SCOPUS, Google Scholar, and PubMed were searched using 42 search terms and their combinations to identify manuscripts, reports, and directives published between 1971 and 2019. The search was then extended to the reference lists of relevant articles. The calculated median, as well as the mean, concentration of NO 2 in school (median 21.1 μg/m3; mean 29.4 μg/m3) and office settings (median 22.7 μg/m3; mean 25.1 μg/m3) was well below the World Health Organization (WHO) guideline of 40 μg/m3 for the annual mean NO 2 concentration. However, a large range of average concentrations of NO 2 were reported, from 6.00 to 68.5 μg/m3 and from 3.40 to 56.5 μg/m3 for school and office environments, respectively, indicating situations where the WHO guidelines are exceeded. Outdoor levels of NO 2 are a reliable predictor of indoor NO 2 levels across seasons, with mean and median Indoor/Outdoor (I/O) ratios of 0.9 and 0.7 in school and 0.9 and 0.8 in office environments, respectively. The absence of major indoor NO 2 emission sources and NO 2 sinks, including chemical reactions and deposition, are the reasons for lower indoor NO 2 concentrations. During the winter, outdoor NO 2 concentrations are generally higher than during the summer. In addition, various building and indoor environment characteristics, such as type of ventilation, air exchange rates, airtightness of the envelope, furnishing and surface characteristics of the building, location of the building (urban versus suburban and proximity to traffic routes), as well as occupants' behavior (such as opening windows), have been statistically significantly associated with indoor NO 2 levels in school and office environments. Indoor exposure to NO 2 from the infiltration of ambient air can be significant in urban areas, and in the case of high traffic volume. Although reducing transportation emissions is challenging, there are several easier means to reduce indoor NO 2 concentrations, including a ventilation strategy with suitable filters; location planning of new schools, classrooms, and ventilating windows or intakes; traffic planning (location and density); and reducing the use of NO 2 -releasing indoor sources. • The level of NO 2 in ambient air is strongly related to the population and traffic density. • NO 2 is a health risk in outdoor and indoor air, and must be minimized. • The median indoor concentration of NO 2 was 26.1 μg/m3 and 22.7 μg/m3 in schools and offices, respectively. • The median Indoor/Outdoor (I/O) NO 2 ratio was 0.7 and 0.8 in schools and offices, respectively. • The mean NO 2 concentration in schools and offices is statistically significantly higher in Oceania and Asia than in Europe. [ABSTRACT FROM AUTHOR]

Details

Language :
English
ISSN :
01604120
Volume :
130
Database :
Academic Search Index
Journal :
Environment International
Publication Type :
Academic Journal
Accession number :
137853295
Full Text :
https://doi.org/10.1016/j.envint.2019.05.081