Back to Search Start Over

A label-free photoelectrochemical aptasensing platform base on plasmon Au coupling with MOF-derived In2O3@g-C3N4 nanoarchitectures for tetracycline detection.

Authors :
Feng, Yixuan
Yan, Tao
Wu, Tingting
Zhang, Ning
Yang, Qianqian
Sun, Meng
Yan, Liangguo
Du, Bin
Wei, Qin
Source :
Sensors & Actuators B: Chemical. Nov2019, Vol. 298, pN.PAG-N.PAG. 1p.
Publication Year :
2019

Abstract

• A novel photoelectrochemical aptasensor for the detection of Tc was designed. • MIL-68 (In) derived In 2 O 3 nanoparticles were employed as substrate to fabricate PEC aptasensor for the first time. • Au-In 2 O 3 @g-C 3 N 4 nanoarchitectures performed outstanding photoelectrochemical activity. • The aptasensor exhibited a low detection limit of 3.3 pM. A label-free photoelectrochemical (PEC) aptasensor for tetracycline (Tc) detection was successfully fabricated, and plasmon Au coupling with MOF-derived In 2 O 3 @g-C 3 N 4 nanoarchitectures (AuInCN) with excellent PEC performance was employed as matrix for the first time. The homogeneous In 2 O 3 nanoparticles (In 2 O 3 NPs) derived from MIL-68(In) precursor were synthesized via calcination in air. The g-C 3 N 4 nanosheets provided a favorable substrate for the fine distribution of In 2 O 3 NPs. The In 2 O 3 @g-C 3 N 4 (InCN) heterojunction with compact interface and matching band structure, facilitated the separation and transfer of electron-hole pairs. The surface plasmon resonance (SPR) of gold nanoparticles (Au NPs) could improve the light absorption and the photoelectron transfer of the modified electrode. Meanwhile, the decorated cysteamine stabilized Au NPs were also adequate to immobilize the SH-terminated aptamer as a biorecognition unit, and Tc molecules could be trapped through the specific interaction with the immobilized aptamer. An enhanced PEC photocurrent was realized under visible light illumination, due to the oxidation of captured Tc by photo-generated holes. Thereby, the concentration of Tc could be detected by observing the changes of photocurrent signals. Under optimized conditions, the PEC aptasensor exhibited the linear range from 0.01 nmol L−1 to 500 nmol L−1, with a detection limit (S/N = 3) of 3.3 pmol L−1. The prepared PEC aptasensor demonstrated acceptable stability, specificity and reproducibility, indicating the potential applications for the detection of Tc. [ABSTRACT FROM AUTHOR]

Details

Language :
English
ISSN :
09254005
Volume :
298
Database :
Academic Search Index
Journal :
Sensors & Actuators B: Chemical
Publication Type :
Academic Journal
Accession number :
138228314
Full Text :
https://doi.org/10.1016/j.snb.2019.126817