Back to Search Start Over

99mTc-MIBI SPECT/CT imaging had high sensitivity in accurate localization of parathyroids before parathyroidectomy for patients with secondary hyperparathyroidism.

Authors :
Zeng, Ming
Liu, Wei
Zha, Xiaoming
Tang, Shaowen
Liu, Jin
Yang, Guang
Mao, Huijuan
Yu, Xiangbao
Sun, Bin
Zhang, Bo
Ouyang, Chun
Zhang, Lina
Guo, Jing
Wang, Jing
Huang, Yaoyu
Purrunsing, Yogendranath
Qian, Hanyang
Wang, Ningning
Xing, Changying
Source :
Renal Failure. Nov2019, Vol. 41 Issue 1, p885-892. 8p. 3 Diagrams, 3 Charts.
Publication Year :
2019

Abstract

Purpose: Accurate preoperative parathyroid localization is important for successful parathyroidectomy (PTX). The aim of our study was to investigate whether SPECT/CT has enhanced effect in preoperative localization of parathyroids. Methods: In our retrospective cohort study, we evaluated the effects of technetium-99m methoxyisobutylisonitrile-single-photon emission computed tomography/computed tomography (99mTc-MIBI SPECT/CT) on preoperative parathyroid localization for 645 secondary hyperparathyroidism (SHPT) patients. Among them, 569 successful PTX patients were divided into group A (received 99mTc-MIBI scintigraphy, n = 175) and group B (received 99mTc-MIBI scintigraphy and SPECT/CT imaging, n = 394). Sensitivity, specificity, and consistency of two imaging methods in preoperative localization of parathyroids were compared. Results: Overall sensitivity and consistency were higher in group B, while there was no difference in specificity between the two groups. In group A, the sensitivity of 99mTc-MIBI was 50.00%, 77.11%, 61.76%, and 76.54% in the right upper gland (RU), right lower gland (RL), left upper gland (LU), and left lower gland (LL) subgroups, while the consistency was 52.00%, 76.57%, 61.71%, and 75.43%, respectively. In group B, the sensitivity of 99mTc-MIBI with SPECT/CT was 69.39%, 90.03%, 78.07%, and 84.27%, and the consistency was 69.54%, 88.32%, 78.43%, and 84.26%, respectively. The sensitivity and consistency in lower glands were higher than in upper glands in both groups. Sensitivity for eutopic parathyroid was higher in group B, while there was no difference for ectopic parathyroid. Conclusions:99mTc-MIBI SPECT/CT can increase the sensitivity and consistency of preoperative localization of eutopic parathyroid glands, and it can accurately locate ectopic parathyroid without sensitivity improvement. [ABSTRACT FROM AUTHOR]

Details

Language :
English
ISSN :
0886022X
Volume :
41
Issue :
1
Database :
Academic Search Index
Journal :
Renal Failure
Publication Type :
Academic Journal
Accession number :
140918828
Full Text :
https://doi.org/10.1080/0886022X.2019.1662804