The use of a double-layer platinum black-conducting polymer coating for improvement of neural recording and mitigation of photoelectric artifact.

Authors :
Wang, Long-Chun
Wang, Ming-Hao
Ge, Chao-Fan
Ji, Bo-Wen
Guo, Zhe-Jun
Wang, Xiao-Lin
Yang, Bin
Li, Cheng-Yu
Liu, Jing-Quan
Source :
Biosensors & Bioelectronics. Dec2019, Vol. 145, pN.PAG-N.PAG. 1p.
Publication Year :
2019

Abstract

The impedance of electrode and photostimulation artifacts (short-duration and high-amplitude spikes) are still hindering the employment of silicon-based neural probe in optogenetics. A fiber-based optrode modified with a double-layer platinum black-poly (3,4ethylenedioxythiophene) PEDOT/poly (4-styrenesulfonate) PSS (Pt-PP) coating has been developed for improvement of neural recording quality and mitigation of photoelectric artifact simultaneously. The Pt-PP coating was made by layer-by-layer electrochemical deposition followed by the ultrasonication and Cyclic Voltammetry (CV) scanning to verify its mechanical and electrochemical stability. Both in-vitro and in-vivo experiments demonstrated that Pt-PP coated optrode had outstanding recording performance (high signal-to-noise ratio about 9.64) and low photoelectric amplitude (850 μV). The artifact recovery time of Pt-PP coated optrode (0.3 ms) after photostimulation was significantly decreased when compared to platinum black (6 ms) or PEDOT/PSS (0.7 ms) coated one which has potential to retain high-quality neural signals in animal experiments. At last, the optogenetics experiments revealed the capability of Pt-PP coated optrode to record the change in neural spike rate with certain spatial resolution and shorter artifact recovery time. These results suggest that Pt-PP coating has great potential for neural electrodes in the application of neuroscience. • A layer-by-layer electrochemical deposition Platinum black-PEDOT/PSS (Pt-PP) coating on microelectrode is described. • The design and in vivo application of a fiber based Michigan optrode with flexibility PI connection is verified. • The performance of recording and mitigation of photoelectric of Pt-PP modified optrode are better than Platinum Black and PEDOT/PSS modified one. • The mechanical and electrochemical stability of Pt-PP modified optrode were verified by ultrasonication and CV scanning tests. • The Pt-PP modified optrode recorded higher quality spikes with lower artifact amplitude, shorter recovery time during optogenetics experiments. [ABSTRACT FROM AUTHOR]

Details

Language :
English
ISSN :
09565663
Volume :
145
Database :
Academic Search Index
Journal :
Biosensors & Bioelectronics
Publication Type :
Academic Journal
Accession number :
140984422
Full Text :
https://doi.org/10.1016/j.bios.2019.111661