Back to Search Start Over

Automated Cutting Plane Positioning for Intracranial Aneurysm Quantification.

Authors :
Jerman, Tim
Chien, Aichi
Pernus, Franjo
Likar, Bostjan
Spiclin, Ziga
Source :
IEEE Transactions on Biomedical Engineering. Feb2020, Vol. 67 Issue 2, p577-587. 11p.
Publication Year :
2020

Abstract

Objective: Aneurysm rupture risk can be assessed by its morphologic and hemodynamics features extracted based on angiographic images. Feature extraction entails aneurysm isolation, typically by manually positioning a cutting plane (MCP). To eliminate intra- and inter-rater variabilities, we propose automatic cutting plane (ACP) positioning based on the analysis of vascular surface mesh. Methods: Innovative Hough-like and multi-hypothesis-based detection of aneurysm center, parent vessel inlets, and centerlines were proposed. These were used for initialization and iterative ACP positioning by geometry-inspired cost function optimization. For validation and baseline comparison, we tested MCP and manual neck curve-based isolation. Isolated aneurysm morphology was characterized by size, dome height, aspect ratio, and nonsphericity index. Results: Methods were applied to 55 intracranial saccular aneurysms from two sites, involving 3-D digital subtraction angiography, computed tomography angiography, and magnetic resonance angiography modalities. Isolation based on ACP resulted in smaller average inter-curve distances (AICDs), compared to those obtained by MCP. One case had AICD higher than 1.0 mm, while 90% of cases had AICD $< $ 0.5 mm. Intra- and inter-rater AICD variability of manual neck curves was higher compared to MCP, validating its robustness for clinical purposes. Conclusion: The ACP method achieved high accuracy and reliability of aneurysm isolation, also confirmed by expert visual analysis. So extracted morphologic features were in good agreement with MCP-based ones, therefore, ACP has great potential for aneurysm morphology and hemodynamics quantification in clinical applications. Significance: The novel method is angiographic modality agnostic; it delivers repeatable isolation important in follow-up aneurysm assessment; its performance is comparable to MCP; and re-evaluation is fast and simple. [ABSTRACT FROM AUTHOR]

Details

Language :
English
ISSN :
00189294
Volume :
67
Issue :
2
Database :
Academic Search Index
Journal :
IEEE Transactions on Biomedical Engineering
Publication Type :
Academic Journal
Accession number :
141418546
Full Text :
https://doi.org/10.1109/TBME.2019.2918921