Back to Search Start Over

A novel disposable electrochemical sensor based on modifying graphite pencil lead electrode surface with nanoacetylene black for simultaneous determination of antiandrogens flutamide and cyproterone acetate.

Authors :
Ibrahim, Hossieny
Temerk, Yassien
Source :
Journal of Electroanalytical Chemistry. Feb2020, Vol. 859, pN.PAG-N.PAG. 1p.
Publication Year :
2020

Abstract

A novel nanoacetylene black coated the surface of graphite pencil lead electrode (nano-AB/GPLE) is successfully constructed. Electrochemical impedance spectroscopy (EIS) and cyclic voltammetry (CV) indicated that the new designed nano-AB/GPLE possessed a fast electron transfer compared with the bare GPLE and enhanced electrochemical response toward electroreduction of antiandrogens flutamide (FLU) and cyproterone acetate (CPA) simultaneously. From the nano-AB/GPLE, two well separated reduction signals of coexistence FLU and CPA at nano-AB/GPLE were obtained. Electrochemical sensing of FLU and CPA in the presence of the physiological common interferents at nano-AB/GPLE was examined and confirmed the selectivity for the detection analysis of the two antiandrogens without cross interference of biological compounds. The limits of detection for coexistence of FLU and CPA are 1.39 nM and 4.74 nM, respectively. Finally, the applicability of the designed sensor is performed for detection of the two antiandrogens FLU and CPA simultaneously in pharmaceutical tablets and biological fluids with good accuracy and precision. A novel disposable electrochemical sensor based on nanoacetylene black (nano-AB) coated graphite pencil lead electrode (nano-AB/GPLE) was fabricated. The new sensor was applied for the simultaneous determination of the prostate anticancer drugs flutamide (FLU) and cyproterone acetate (CPA) in real samples. Unlabelled Image • A new design of a mechanical pencil holder was constructed to reduce the voltammetric analysis time usage. • A novel disposable sensor based on nano-AB coated graphite pencil lead electrode (nano-AB/GPLE) was fabricated. • The sensitive sensor was applied for the determination of antiandrogens flutamide and cyproterone acetate in real samples. • The new electrode showed good stability, sensitivity and selectivity and low detection limits [ABSTRACT FROM AUTHOR]

Details

Language :
English
ISSN :
15726657
Volume :
859
Database :
Academic Search Index
Journal :
Journal of Electroanalytical Chemistry
Publication Type :
Academic Journal
Accession number :
142001387
Full Text :
https://doi.org/10.1016/j.jelechem.2020.113836