Back to Search Start Over

Semi-quantitative myocardial perfusion MRI in heart transplant recipients at rest: repeatability in healthy controls and assessment of cardiac allograft vasculopathy.

Authors :
DeSa, Travis B.
Abbasi, Muhannad A.
Blaisdell, Julie A.
Lin, Kai
Collins, Jeremy D.
Carr, James C.
Markl, Michael
Source :
Clinical Imaging. May2020, Vol. 61, p62-68. 7p.
Publication Year :
2020

Abstract

Cardiac Allograft Vasculopathy (CAV) is a major cause of chronic cardiac allograft failure. Invasive coronary angiography (ICA) and intravascular ultrasound (IVUS) are the current diagnostic methods. Myocardial perfusion MRI has become a promising non-invasive method to evaluate myocardial ischemia, but has not been thoroughly validated in CAV. Our objective was to assess the repeatability of myocardial rest-perfusion MRI in healthy volunteers and its feasibility in detecting CAV in transplant patients (Tx). Twelve healthy volunteers and twenty transplant patients beyond the first year post- transplant underwent cardiac MRI at 1.5 T at rest including first-pass perfusion imaging in short axis (base, mid, apex) after injection of gadolinium. Volunteers underwent repeated cardiac MRI on different days (interval = 15.6 ± 2.4 days) to assess repeatability. Data analysis included semi-automatic contouring of endocardial and epicardial borders of the left ventricle (LV) and quantification of peak perfusion, time-to-peak (TTP) perfusion, and upslope of the perfusion curve. Between scans and re-scans in healthy volunteers, peak signal intensity, slope, and TTP demonstrated moderate agreement (ICC = 0.53, 0.48, and 0.59, respectively; all, p <.001). Peak signal intensity, slope, and TTP were moderately variable with COV values of 23%, 42%, and 35%, respectively. Peak perfusion was significantly reduced in CAV positive (n = 9 Tx patients) compared to CAV negative (n = 11 Tx patients) groups (90.7 ± 27.0 vs 139.5 ± 30.2, p <.001). Cardiac MRI is a moderately repeatable method for the semi-quantitative assessment of first-pass myocardial perfusion at rest. Semi-quantitative surrogate markers of LV perfusion could play a role in CAV detection. • Cardiac MR is a moderately repeatable method of imaging cardiac perfusion. • Cardiac MR detected lower perfusion in Cardiac Allograft Vasculopathy (CAV) at rest. • CAV perfusion differences were apparent on global and segmental levels at rest. [ABSTRACT FROM AUTHOR]

Details

Language :
English
ISSN :
08997071
Volume :
61
Database :
Academic Search Index
Journal :
Clinical Imaging
Publication Type :
Academic Journal
Accession number :
142297019
Full Text :
https://doi.org/10.1016/j.clinimag.2019.12.011