Acute appendicitis within a robotic port-site hernia: a case report.
- Source :
-
Journal of Surgical Case Reports . Feb2020, Vol. 2020 Issue 2, pN.PAG-N.PAG. 1p. - Publication Year :
- 2020
-
Abstract
- Trocar-site hernias are uncommon complications of minimally invasive surgery. The potential for incarceration or strangulation of intra-abdominal contents within trocar-site hernias can lead to major morbidity. We present a case of acute, strangulated appendicitis within a right lower quadrant 8 mm robotic trocar site following robot-assisted laparoscopic cholecystectomy. We additionally perform a brief review of the literature regarding the optimal approach to trocar-site closure. [ABSTRACT FROM AUTHOR]