Back to Search Start Over

Effect of temperatures on self-healing capabilities of concrete with different shell composition microcapsules containing toluene-di-isocyanate.

Authors :
Du, Wei
Yu, Jianying
Gu, Shunjie
Wang, Ruiyang
Li, Jiangting
Han, Xiaobin
Liu, Quantao
Source :
Construction & Building Materials. Jun2020, Vol. 247, pN.PAG-N.PAG. 1p.
Publication Year :
2020

Abstract

• Self-healing capabilities of mortars under different temperatures were investigated. • Self-healing capabilities of mortars with microcapsules increased from 10 °C to 50 °C. • Crack of mortar with nano-SiO 2 /paraffin/PE wax microcapsule self-healed in 3 h at 50 °C. The ambient temperatures have significant effect on self-healing capabilities of concretes with microcapsules. Self-healing capabilities of mortars with different shell composition (paraffin, paraffin/PE wax and nano-SiO 2 /paraffin/PE wax) microcapsules containing toluene-di-isocyanate under the temperature of 10 °C, 30 °C, 50 °C and 60 °C were investigated in this paper. The compressive strength, chloride diffusion coefficient and pore size distribution of mortars containing microcapsules before and after self-healing were characterized by mechanical property test, rapid chloride migration test and nuclear magnetic resonance, respectively. The crack healing ratio of mortars during self-healing period were measured. The self-healing capabilities of mortars containing different microcapsules raised with the increase from 10 °C to 50 °C. Nevertheless, when the temperature reached 60 °C, the self-healing capability of the mortar containing paraffin microcapsules (AM1) decreased obviously, while the self-healing capabilities of the mortars containing paraffin/PE wax microcapsules (AM2) and nano-SiO 2 /paraffin/PE wax microcapsules (AM3) were almost unchanged. The self-healing capability of AM3 was superior to that of AM1 and AM2 at the same temperature. The compressive strength recovery rate, chloride diffusion coefficient recovery rate and harmful pores ratios of AM3 after pre-damaged at 50 °C for 7 d self-healing were 94.1%, 81.2% and 47.3%, respectively. When the ambient temperature reached 50 °C, the surface cracks of the mortar with three kinds of microcapsules could be completely self-healed in 5 h. However, when the temperature raised to 60 °C, the healing ratio of the crack in AM1 with a width of 0.4–0.5 mm decreased to 49.52% after 6 h self-healing. Meanwhile, the surface cracks of AM3 could be completely self-healed less than 3 h. [ABSTRACT FROM AUTHOR]

Details

Language :
English
ISSN :
09500618
Volume :
247
Database :
Academic Search Index
Journal :
Construction & Building Materials
Publication Type :
Academic Journal
Accession number :
142852824
Full Text :
https://doi.org/10.1016/j.conbuildmat.2020.118575