Back to Search Start Over

Heat transfer and flow characteristics in a rectangular channel with miniature square column in aligned and staggered arrangements.

Authors :
Wang, Jiansheng
Sun, Zeyu
Liu, Xueling
Source :
International Journal of Thermal Sciences. Sep2020, Vol. 155, pN.PAG-N.PAG. 1p.
Publication Year :
2020

Abstract

In the present work, Large Eddy Simulation (LES) is employed to investigate the heat transfer performance and flow characteristic in a rectangular channel with three-row miniature square column vortex generators (MSCVGs) as Reynolds number varies from 3745 to 11,235. The height of the MSCVGs is less than the thickness of the boundary layer, and MSCVGs arrays arranged in the form of aligned and staggered. In aligned and staggered arrangements, the spanwise distance between adjacent MSCVGs in the same row is 100 and 200 wall units, respectively. The numerical result indicates that the wake induced by the MSCVGs arrays has an obvious impact on the boundary layer. The wakes induced by the MSCVGs in aligned and staggered arrangements act as the "restricted belt" and "restricted plate" respectively, which can particularly alter and adjust the original flow structures, velocity streaks and vortices in the boundary layer. For the aligned array arrangement, the wakes induced by MSCVGs can improve the heat transfer performance of the channel as well as obtain the drag reduction. For the staggered array arrangement, the frictional coefficient of the channel decreases by up to 11.95%, and the Nusselt number decreases slightly with the effective reduction of the frictional resistance. The overall performance coefficient of the channel with three-row MSCVGs in staggered or aligned arrangements are both greater than 1 in all considered Reynolds number ranges, which means that MSCVGs arrays can enhance the overall thermal performance of the channel. • The height of MSCVG is far less than the thickness of boundary layer. • MSCVGs in aligned and staggered arrangement keep the same projection spanwise spacing. • The wakes induced by MSCVGs in aligned and staggered work as the "restricted belt" and "restricted plate", respectively. • For aligned array, the augment of heat transfer and reduction of frictional resistance are obtained simultaneously. • The MSCVGs arrays in staggered and aligned both improve the overall performance of the channel in all considered Reynolds number ranges. [ABSTRACT FROM AUTHOR]

Details

Language :
English
ISSN :
12900729
Volume :
155
Database :
Academic Search Index
Journal :
International Journal of Thermal Sciences
Publication Type :
Academic Journal
Accession number :
143365745
Full Text :
https://doi.org/10.1016/j.ijthermalsci.2020.106413