Back to Search Start Over

Atomic Clock Performance Assessment of BeiDou-3 Basic System with the Noise Analysis of Orbit Determination and Time Synchronization.

Authors :
Jia, Xiaolin
Zeng, Tian
Ruan, Rengui
Mao, Yue
Xiao, Guorui
Source :
Remote Sensing. Dec2019, Vol. 11 Issue 24, p2895. 1p.
Publication Year :
2019

Abstract

The basic system of the BeiDou global navigation satellite system (BDS-3) with 18 satellites has been deployed since December 2018. As the primary frequency standard, BDS-3 satellites include two clock types with the passive hydrogen maser (PHM) and the rubidium atomic frequency standard (RAFS). Based on the final precise orbit and clock product from Xi'an Research Institute of Surveying and Mapping (XRS), the atomic clock performance of BDS-3 satellites is evaluated, including the frequency accuracy, frequency drift rate, and frequency stability, and compared with GPS block IIF satellites with RAFS, Galileo satellites with PHM, and BDS-2 satellites. A data auto-editing procedure to preprocess clock data and assess the clock performance is developed, where the assessed results are derived at each continuous data arc and the outliers are excluded properly. The stability of XRS product noise is given by using some stations equipped with high-precision active hydrogen masers (AHM). The best stability is 8.93 × 10−15 and 1.85 × 10−15 for the averaging time of 10,000 s and 1 day, which is basically comparable to one-third of the in-orbit PHM frequency stability. The assessed results show the average frequency accuracy and drift rate of BDS-3 with RAFS are slightly worse while the stability is better than BDS-2 medium earth orbit (MEO) satellites. The 10,000 s stability is better but the 1-day stability is worse than GPS, which may be related to the performance of the BDS-3 RAFS clock. As for BDS-3 with PHM, the frequency accuracy is slightly worse than Galileo PHM satellites; the drift rate, when excluding C34 and C35, is basically comparable to Galileo and significantly better than GPS satellites; the stability is comparable to Galileo, where the 10,000 s stability is slightly worse than Galileo and better than GPS. The 1-day stability among BDS-3 PHM, GPS IIF RAFS, and Galileo PHM satellites is basically comparable. [ABSTRACT FROM AUTHOR]

Details

Language :
English
ISSN :
20724292
Volume :
11
Issue :
24
Database :
Academic Search Index
Journal :
Remote Sensing
Publication Type :
Academic Journal
Accession number :
145160515
Full Text :
https://doi.org/10.3390/rs11242895