• The efficiency factor of direct expansion PVT module is derived and validated. • Proposed a novel design method for PVT module employing roll-bond evaporator. • Parameter analysis is conducted to evaluate the thermal performance of four different channel patterns. • Hexagon and rectangle types have better temperature uniformity while grid and linear types have lower pressure loss. Direct expansion solar assisted PVT (photovoltaic/thermal) heat pump is a combination of PVT technology and heat pump technology, which can improve the comprehensive conversion efficiency of solar energy, and it is suitable for solar heating applications. In this paper, the efficiency factor of direct expansion PVT module employing roll-bond panel has been theoretically derived, modified, and validated by experimental results. Moreover, the efficiency factor could be used to design, evaluate, and optimize the thermal performance of direct expansion solar assisted heat pump systems. In addition, parameter analysis of four evaporator unit types has been conducted, and the recommendation values of each parameter have also been presented. The simulation results show that the roll-bond evaporator (fluid channel width: 10 mm) with hexagon and rectangle patterns have better temperature distribution uniformity than grid and linear types, and their temperature differences are both 0.038 °C while their dimensionless pressure losses are 0.109 and 0.230, respectively. To specifically design different kinds of PVT collector/evaporator or direct expansion evaporators, a novel design method for roll-bond evaporator is proposed, and a combination of hexagon and grid types is recommended for PVT module. Moreover, the recommendation fluid channel width of the roll-bond panel is 8 mm to 13 mm while the scaling ratio is 0.8 to 1.2. The modified efficiency factors are 0.521, 0.564, 0.549, and 0.342 of hexagon, grid, rectangle, and linear types when the fluid channel width is 10 mm, respectively. [ABSTRACT FROM AUTHOR]

Details

Language :
English
ISSN :
0038092X
Volume :
206
Database :
Academic Search Index
Journal :
Solar Energy
Publication Type :
Academic Journal
Accession number :
145498696
Full Text :
https://doi.org/10.1016/j.solener.2020.04.053