Energy consumption analysis in wastewater treatment plants using simulation and SCADA system: Case study in northern Taiwan.

Authors :
Sean, Wu-Yang
Chu, Ya-Yun
Mallu, Lili Lorensia
Chen, Jian-Gu
Liu, Han-Yang
Source :
Journal of Cleaner Production. Dec2020, Vol. 276, pN.PAG-N.PAG. 1p.
Publication Year :
2020

Abstract

Energy consumption is a crucial aspect in wastewater treatment plants. Biological processes using aeration systems contribute significantly to energy usage. Tao-bay plants in northern Taiwan are recent plants that have not introduced automated control on aeration systems yet. The use of numerical methods aims to predict optimized airflow rate and energy consumption and to provide references for the first-phase plant operation. In this study, a steady-state modeling using GPS-X 7.0 is presented. Measured monthly data in a yearly basis for parameters such as BOD, COD, total N, N–NH 4 +, and total P were used as the input data. The measured effluent concentrations for these parameters were compared with numerically calculated values for calibration purposes. An empirical correlation is also proposed for an alternative calculation of airflow and relative electricity consumption. A supervisory control and data acquisition (SCADA) system that consisted of current and water quality sensors with an online interface was developed to monitor the aeration system of the case-study plant. Selected real-time data for DO and electricity usage related to the biological treatment were recorded in the cloud server and used for verifying and compensating existing data measured in the plant. According to the monthly energy-consumption data for Tao-bay plant in 2018, the energy-saving rate predicted using the GPS-X model was approximately 20%, which is consistent with the global values (18–21%) of the plant operating in the range of 50,000–10,000 CMD. Moreover, when adjusting DO every 1 mg/L to fit a sewage-discharge criterion, the energy-saving rate was approximately 5–7%. • This research is for the prediction of the optimized airflow rate and energy usage. • SCADA system with real-time monitoring interface is built to collect the electricity in SQL database. • To adjust DO every 1 mg/L improves energy-saving rate about 5-7%. [ABSTRACT FROM AUTHOR]

Details

Language :
English
ISSN :
09596526
Volume :
276
Database :
Academic Search Index
Journal :
Journal of Cleaner Production
Publication Type :
Academic Journal
Accession number :
146482946
Full Text :
https://doi.org/10.1016/j.jclepro.2020.124248