Back to Search Start Over

Retrieval and Validation of XCO2 from TanSat Target Mode Observations in Beijing.

Authors :
Bao, Zhengyi
Zhang, Xingying
Yue, Tianxiang
Zhang, Lili
Wang, Zong
Jiao, Yimeng
Bai, Wenguang
Meng, Xiaoyang
Source :
Remote Sensing. Sep2020, Vol. 12 Issue 18, p3063. 1p.
Publication Year :
2020

Abstract

Satellite observation is one of the main methods used to monitor the global distribution and variation of atmospheric carbon dioxide (CO2). Several CO2 monitoring satellites have been successfully launched, including Japan's Greenhouse Gases Observing SATellite (GOSAT), the USA's Orbiting Carbon Observatory-2 (OCO-2), and China's Carbon Dioxide Observation Satellite Mission (TanSat). Satellite observation targeting the ground-based Fourier transform spectrometer (FTS) station is the most effective technique for validating satellite CO2 measurement precision. In this study, the coincident observations from TanSat and ground-based FTS were performed numerous times in Beijing under a clear sky. The column-averaged dry-air mole fraction of carbon dioxide (XCO2) obtained from TanSat was retrieved by the Department for Eco-Environmental Informatics (DEEI) of China's State Key Laboratory of Resources and Environmental Information System based on a full physical model. The comparison and validation of the TanSat target mode observations revealed that the average of the XCO2 bias between TanSat retrievals and ground-based FTS measurements was 2.62 ppm, with a standard deviation (SD) of the mean difference of 1.41 ppm, which met the accuracy standard of 1% required by the mission tasks. With bias correction, the mean absolute error (MAE) improved to 1.11 ppm and the SD of the mean difference fell to 1.35 ppm. We compared simultaneous observations from GOSAT and OCO-2 Level 2 (L2) bias-corrected products within a ±1° latitude and longitude box centered at the ground-based FTS station in Beijing. The results indicated that measurements from GOSAT and OCO-2 were 1.8 ppm and 1.76 ppm higher than the FTS measurements on 20 June 2018, on which the daily observation bias of the TanSat XOC2 results was 1.87 ppm. These validation efforts have proven that TanSat can measure XCO2 effectively. In addition, the DEEI-retrieved XCO2 results agreed well with measurements from GOSAT, OCO-2, and the Beijing ground-based FTS. [ABSTRACT FROM AUTHOR]

Details

Language :
English
ISSN :
20724292
Volume :
12
Issue :
18
Database :
Academic Search Index
Journal :
Remote Sensing
Publication Type :
Academic Journal
Accession number :
146537807
Full Text :
https://doi.org/10.3390/rs12183063