Back to Search
Start Over
Functioning of the radiation life-support system in the spring period.
- Source :
-
AIP Conference Proceedings . 2020, Vol. 2285 Issue 1, p1-8. 8p. - Publication Year :
- 2020
-
Abstract
- Experimental studies conducted in the spring of 2018 and 2019 in the highly continental climate of Western Siberia made it possible to draw a number of conclusions about the applicability of the radiation life - support system for cottages, rural houses, and other detached buildings. During the research, more than 50 million experimental temperature measurements were taken with their recording in the memory of logger 88598. Temperatures were recorded on a measuring cell with an air heat insulation of the experimental stand. The obtained experimental data were processed, as a result of which the specific heat output (kW*h/m2) was determined per day of operation of the radiation heating system in the spring months of 2019, calculated by integrating the current power of the radiation heating system. In the spring, at night, the radiation collector cools slightly below ambient air. In addition, the ambient air in the spring period during the dark is usually colder than the indoor temperature. Therefore, in the spring season, instead of radiation conditioning, it is reasonable to use ventilation. [ABSTRACT FROM AUTHOR]
- Subjects :
- *HEATING
*RURAL housing
*SPRING
*RADIATION
*THERMAL insulation
*SPECIFIC heat
Subjects
Details
- Language :
- English
- ISSN :
- 0094243X
- Volume :
- 2285
- Issue :
- 1
- Database :
- Academic Search Index
- Journal :
- AIP Conference Proceedings
- Publication Type :
- Conference
- Accession number :
- 147077606
- Full Text :
- https://doi.org/10.1063/5.0029930