Back to Search Start Over

Multiā€resonators, microwave microfluidic sensor for liquid characterization.

Authors :
Abduljabar, Ali A.
Hamzah, Hayder
Porch, Adrian
Source :
Microwave & Optical Technology Letters. Apr2021, Vol. 63 Issue 4, p1042-1047. 6p.
Publication Year :
2021

Abstract

In this paper, a new type of microwave microfluidic sensor is presented, using three separate half wave microstrip resonators with a common junction. The sensor comprises three parallel resonators with resonant frequencies of 2.5, 3.5, and 4.5 GHz. This sensor exhibits all the usual advantages of microwave resonant methods for dielectric liquid characterization, such as high precision, accuracy, and sensitivity, but here also over a wideband of frequencies. The resonators have common input and output ports. The sensor was tested using several types of liquids, including water, methanol, ethanol, and chloroform, and experimental results are in excellent agreement with the simulation results. [ABSTRACT FROM AUTHOR]

Details

Language :
English
ISSN :
08952477
Volume :
63
Issue :
4
Database :
Academic Search Index
Journal :
Microwave & Optical Technology Letters
Publication Type :
Academic Journal
Accession number :
148998352
Full Text :
https://doi.org/10.1002/mop.32675