Back to Search Start Over

A simple building energy model in form of an equivalent outdoor temperature.

Authors :
Cholewa, Tomasz
Siuta-Olcha, Alicja
Smolarz, Andrzej
Muryjas, Piotr
Wolszczak, Piotr
Anasiewicz, Rafał
Balaras, Constantinos A.
Source :
Energy & Buildings. Apr2021, Vol. 236, pN.PAG-N.PAG. 1p.
Publication Year :
2021

Abstract

• Method for generation of simple building energy model. • Influence of wind speed and solar radiation on energy consumption. • Account for the real efficiency of the installed heating system in the calculations. • Building energy model allows accurate short-term forecasting of heat supply. Smart control of energy supply to the existing buildings may increase their energy efficiency. However, to the best of the authors' knowledge, there are no simple, general, automated, widely applicable and accurate methods for the creation of energy model of the building, which may be used to calculate the actual energy consumption of a heating system or for their prediction. This work presents a new simplified method for generating the energy characteristics of buildings and their heating systems, without the influence of occupants. The method requires as input only the actual heat supplied to the heating system and the local outdoor weather conditions (i.e. temperature, wind speed and solar insolation) of a building. The output is a building energy model in terms of an equivalent outdoor temperature. It was found that when determining the correction due to the wind, the data from the night hours (e.g. from 11.00 p.m. to 4.00 a.m.) should be used in order to exclude the impact of solar radiation and minimize the interaction of users. On the other hand, the correction due to the influence of solar radiation should be obtained using data with low wind speeds and time periods from 10.00 a.m. to 2.00 p.m. on weekdays for residential buildings or from 10.00 a.m. to 2.00 p.m. on the weekend for public buildings in order to minimize disruptive effects of wind speed and the impacts from occupants. This method may be used to generate a simple building energy model and to accurately determine the duration and the amount of heat power supplied to a building for space heating, for periods when the impact of occupants and other internal heat gains are kept to a minimum. [ABSTRACT FROM AUTHOR]

Details

Language :
English
ISSN :
03787788
Volume :
236
Database :
Academic Search Index
Journal :
Energy & Buildings
Publication Type :
Academic Journal
Accession number :
149415771
Full Text :
https://doi.org/10.1016/j.enbuild.2021.110766