Comment on "Requirements and sensitivity analysis for temporally- and spatially-resolved thermometry using neutron resonance spectroscopy" [Rev. Sci. Instrum. 90, 094901 (2019)].

Authors :
Swift, Damian C.
McNaney, James M.
Source :
Review of Scientific Instruments. Mar2021, Vol. 92 Issue 3, p1-3. 3p.
Publication Year :
2021

Abstract

Pulses of I o i (10 SP 11 sp ) neutrons may be feasible for single-shot thermometry on other loading platforms, with significant challenges in loading over an adequate area and in protecting the laser source and the detector. Compared with LANSCE experiments using spallation neutrons, laser-accelerated neutrons with a lower initial mean energy do mean that the moderator can be slightly smaller for the same luminosity per neutron. Several further orders of magnitude increase in neutron production are needed before short-pulse laser facilities could usefully perform single-shot NRS thermometry on laser-loaded samples. [Extracted from the article]

Details

Language :
English
ISSN :
00346748
Volume :
92
Issue :
3
Database :
Academic Search Index
Journal :
Review of Scientific Instruments
Publication Type :
Academic Journal
Accession number :
149619894
Full Text :
https://doi.org/10.1063/1.5133415