Electrogenerated chemiluminescence method for sensitive detection of hydroxylated double-stranded DNA through multifunctional polyadenine probe and hybridization chain reaction.

Authors :
Bai, Wanqiao
He, Wenyu
Wang, Huan
Li, Sijia
Yang, Xia
Sun, Huiping
Li, Yan
Source :
Sensors & Actuators B: Chemical. Jun2021, Vol. 336, pN.PAG-N.PAG. 1p.
Publication Year :
2021

Abstract

• A highly sensitive ECL biosensing platform based on polyA-gold interaction and HCR was fabricated. • Multifunctional polyA probe which consists of a recognition part, a polyA part and a signal amplification part was designed. • The ECL method could even detect 5-hmC-dsDNA in mice tissues without sequence preference. 5-Hydroxymethylcytosine (5-hmC), as the sixth base in the mammalian genome, is increasingly regarded as an epigenetic marker with crucial biological functions. Herein, a highly sensitive electrogenerated chemiluminescence (ECL) sensing platform for double-stranded DNA containing 5-hmC (5-hmC-dsDNA) in genome was fabricated, which based on polyadenine-gold interaction combining with signal amplification of hybridization chain reaction (HCR). This biosensing strategy could be executed to detect 5-hmC in the native double-stranded DNA, irrespective of the specific sequences of DNA. Firstly, DNA methyltransferase (M.HhaI) was introduced to chemically modify the hydroxyl of 5-hmC in double-stranded DNA, which converted 5-hmC-dsDNA to amino-derived 5-hmC-dsDNA. Subsequently, DNA sequence containing polyadenine (polyA) was used as an anchor probe to incorporate the derivatized 5-hmC-dsDNA by amide reaction to form compound DNA and then completely assembled onto the gold electrode surface through preferential polyA-gold interaction. Subsequently, two designed DNA hairpin probes which can alternately hybridize with each other were linked to the signal amplification part of multifunctional polyA probes, forming ultra-long nicked double helix structures. Finally, ECL indicator of Ru(phen) 3 2+ molecules were intercalated into the groove of the nicked DNA double helices, resulting greatly increased ECL intensity. Therefore, the quantitatively analysis of 5-hmC-dsDNA could be obtained relied on the relationship between the ECL intensity and 5-hmC-dsDNA content. The detection limit of this method for 5-hmC-dsDNA was 0.0001 % (S/N = 3). Moreover, the biosensing platform was successfully applied to detect 5-hmC-dsDNA in mice tissue samples with satisfactory results, manifesting its great potential application in clinical analysis. [ABSTRACT FROM AUTHOR]

Details

Language :
English
ISSN :
09254005
Volume :
336
Database :
Academic Search Index
Journal :
Sensors & Actuators B: Chemical
Publication Type :
Academic Journal
Accession number :
149712080
Full Text :
https://doi.org/10.1016/j.snb.2021.129722