Comparison of Fault Characteristics According to Winding Configurations for Dual Three-Phase Synchronous Reluctance Motor.
- Source :
-
IEEE Transactions on Industry Applications . May/Jun2021, Vol. 57 Issue 3, p2398-2406. 9p. - Publication Year :
- 2021
-
Abstract
- This article compares the characteristics of a dual three-phase synchronous motor under different operating conditions such as healthy, half-control, and postfault conditions. The inductances are analyzed to confirm the interaction between two three-phase systems, and induced voltages of each phase are measured to verify the interaction behaviors. The postfault characteristics are analyzed under open-circuit faults (single-open-switch and single-open-phase faults) and short-circuit faults (single-short-switch and one-three-phase-short faults). The predicted results are validated by experimental tests. Moreover, the half-control mode is investigated as a strategy to operate with high efficiency and tolerant mode. [ABSTRACT FROM AUTHOR]
Details
- Language :
- English
- ISSN :
- 00939994
- Volume :
- 57
- Issue :
- 3
- Database :
- Academic Search Index
- Journal :
- IEEE Transactions on Industry Applications
- Publication Type :
- Academic Journal
- Accession number :
- 150448827
- Full Text :
- https://doi.org/10.1109/TIA.2021.3061039