Back to Search Start Over

Diagnostic Performance of Conventional X-ray for Detecting Foreign Bodies in the Upper Digestive Tract: A Systematic Review and Diagnostic Meta-Analysis.

Authors :
Yang, Ta-Wei
Yu, Yi-Chung
Lin, Yen-Yue
Hsu, Shih-Chang
Chu, Karen Chia-Wen
Hsu, Chin-Wang
Bai, Chyi-Huey
Chang, Cheng-Kuang
Hsu, Yuan-Pin
Corleto, Vito Domenico
Source :
Diagnostics (2075-4418). May2021, Vol. 11 Issue 5, p790. 1p.
Publication Year :
2021

Abstract

Foreign body (FB) ingestion is a common clinical problem in acute settings. Detecting FBs in the upper digestive tract is challenging. The conventional X-ray is usually the first-line imaging tool to detect FBs. However, its diagnostic performance is inconsistent in the literature. In this study, we performed a systematic review and meta-analysis to determine the diagnostic performance of the conventional X-ray for detecting FBs in the upper digestive tract. We conducted a systematic search of PubMed, Embase, Cochrane Library, Web of Science, and Scopus until 1 August 2020. Prospective or retrospective studies investigating the diagnostic accuracy of conventional X-rays for detecting FBs in the upper digestive tract in patients of all ages were included. The Quality Assessment of Studies of Diagnostic Accuracy-2 tool was used to review the quality of included studies. We used a bivariate random-effects model to calculate diagnostic accuracy parameters. Heterogeneity was assessed using I2 statistics. We included 17 studies (n = 4809) in the meta-analysis. Of the 17 studies, most studies were rated as having a high risk of bias. Conventional X-rays had a pooled sensitivity of 0.58 (95% confidence interval [CI] = 0.36–0.77, I2 = 98.52) and a pooled specificity of 0.94 (95% CI = 0.87–0.98, I2 = 94.49) for detecting FBs in the upper digestive tract. The heterogeneity was considerable. The area under the summary receiver operating characteristic curve was 0.91 (95% CI = 0.88–0.93). Deek's funnel plot asymmetry test results revealed no significant publication bias (p = 0.41). The overall sensitivity and specificity of conventional X-rays were low and high, respectively, for detecting FBs in the upper digestive tract. Hence, conventional X-rays to exclude patients without upper FBs in the digestive tract are not recommended. Further imaging or endoscopic examinations should be performed for at-risk patients. [ABSTRACT FROM AUTHOR]

Details

Language :
English
ISSN :
20754418
Volume :
11
Issue :
5
Database :
Academic Search Index
Journal :
Diagnostics (2075-4418)
Publication Type :
Academic Journal
Accession number :
150476781
Full Text :
https://doi.org/10.3390/diagnostics11050790