Measurement of the Second-Order Material Constants of Lanthanum-Gallium Tantalate (LGT) Through Ultrasound.

Authors :
Ju, Shuai
Zhang, Chen
Zahedinejad, Parham
Zhang, Haifeng
Kosinski, John A.
Source :
IEEE Transactions on Ultrasonics Ferroelectrics & Frequency Control. Jun2021, Vol. 68 Issue 6, p2271-2276. 6p.
Publication Year :
2021

Abstract

Lanthanum-gallium tantalate (LGT) is a member of the LGX crystal family (langasite, langanite, and langatate) known for high-quality factor and stability at higher temperatures. These characteristics enable filters and sensors for use in harsh environments. Accurate values for the second-order material constants are required for electromechanical modeling of such devices. A sufficient set of bulk acoustic wave (BAW) propagation velocities have been measured in cube-shaped samples to obtain the full set of second-order elastic and piezoelectric material constants along with the experimental uncertainties. The cross correlation method was used to accurately measure the time-of-flight (TOF) values between the first two back-wall echoes under a constant room-temperature environment. The calculated BAW velocities and extracted material constants show good agreement with earlier work. [ABSTRACT FROM AUTHOR]

Details

Language :
English
ISSN :
08853010
Volume :
68
Issue :
6
Database :
Academic Search Index
Journal :
IEEE Transactions on Ultrasonics Ferroelectrics & Frequency Control
Publication Type :
Academic Journal
Accession number :
150557846
Full Text :
https://doi.org/10.1109/TUFFC.2021.3058326