Abstract

[Display omitted] • The paper introduces a new passive collector design for the purpose of light collection for daylighting. • Maintain uniform lighting levels for the most part of the day under clear sky sun. • The average illuminance of around 400 lx was observed on the floor of the experimental room for the most part of the day. • The performance of proposed designed collectors leads under the low-altitude sun when compared to conventional designs. A tubular skylight (TS) is an effective system for transporting natural sunlight into the building interiors. However, the passive nature of the system may not account for the changing orientation of the sun and the conventional daylight collector designs like transparent dome are less effective under low altitude sun. This paper focuses on the performance evaluation of specifically designed TS having rectilinear parabolic-profile reflectors integrated with plane surface reflectors and wedge-shaped prism for daylight collection. The designed configuration redirects the low altitude incident rays efficiently into a vertical mirror light pipe having a rectangular cross-section and aims at giving desired levels of lighting throughout the sunny day. Numerical analysis of the same was carried out for various sky conditions. Experimental results for the proposed TS design show improved lighting levels during the low-altitude sun and reduced but consistent lighting during the mid-day. Average illuminance of ~ 400 lx was observed on the floor of the experiment room for the most part of the day. Along with capturing beam sunlight a significant amount of diffuse daylight capturing ability under clear sky conditions is observed using the proposed TS. The average illuminance value obtained on the work plane during winter solstice through the most optimized configured TS was more than twice the lighting value achieved by a conventional daylight-collecting transparent dome and almost twice the lighting value achieved by a TS with a prismatic dome collector. Under overcast sky conditions, the performance of the proposed configuration of TS is at par. [ABSTRACT FROM AUTHOR]

Details

Language :
English
ISSN :
0038092X
Volume :
222
Database :
Academic Search Index
Journal :
Solar Energy
Publication Type :
Academic Journal
Accession number :
150575660
Full Text :
https://doi.org/10.1016/j.solener.2021.05.015