Back to Search Start Over

Evaluation of a new foetal shielding device for pregnant brain tumour patients.

Authors :
Kang, Seonghee
Kim, Kyeong-Hyeon
Kang, Sang-Won
Shin, Dong-Seok
Lee, Seungwan
Chung, Jin-Beom
Source :
Radiation Oncology. 6/13/2021, Vol. 16 Issue 1, p1-10. 10p.
Publication Year :
2021

Abstract

<bold>Background: </bold>The present study aimed to propose a new foetal shielding device for pregnant cancer patients to reduce the foetal dose associated with treatment techniques using multiple gantry angles, such as intensity-modulated radiation therapy (IMRT) or volumetric modulated arc therapy (VMAT).<bold>Methods: </bold>Three shielding structures were designed to minimise the scattered and leaked radiation from various gantry angles and radiation scattering within the patient. The base-plate part that can be placed on the treatment couch was designed to reduce the scattered and leaked radiation generated at gantry angles located near 180°. A body shielding part that can cover the lower chest and abdomen was designed, and a neck-shielding structure was added to reduce the internal and external radiation scattering from the treatment area. Evaluation plans were generated to assess the foetal dose reduction by the foetal shielding device in terms of the shielding material thickness, distance from the field edge, and shielding component using the flattened 6 MV photon beam (6MV) and flattening filter-free 6 MV photon beam (6MV-FFF). In addition, the effectiveness of the foetal shielding device was evaluated in a pregnant brain tumour patient.<bold>Results: </bold>The shielding material consisting of three parts was placed on frames composed of four arch shapes with a vertical curved structure, connection bar at the top position, and base plate. Each shielding part resulted in reductions in the radiation dose according to the treatment technique, as the thickness of the shielding material increased and the foetal dose decreased. In addition, a foetal dose reduction of approximately 50% was confirmed at 50 cm from the field edge by using the designed shielding device in most delivery techniques. In patients, the newly designed shielding structures can effectively eliminate up to about 49% of the foetal dose generated from various gantry angles used in VMAT or IMRT.<bold>Conclusions: </bold>We designed a foetal shielding device consisting of three parts to effectively reduce the dose delivered to the foetus, and evaluated the device with various treatment techniques for a pregnant patient with brain tumour. The foetal shielding device shielded the scattered/leaked radiation from the treatment machine, and also effectively reduced internal scattering from the treatment area in the patient. [ABSTRACT FROM AUTHOR]

Details

Language :
English
ISSN :
1748717X
Volume :
16
Issue :
1
Database :
Academic Search Index
Journal :
Radiation Oncology
Publication Type :
Academic Journal
Accession number :
150892642
Full Text :
https://doi.org/10.1186/s13014-021-01836-z