Bone fracture is a severe health concern; therefore, understanding the causes of bone fracture are crucial. This paper investigates the microstructure and fracture behaviour of cadaveric cortical bone of two different groups (Young, n= 6; Aged, n=7). The microstructure is obtained from µ-CT images, and the material parameters are measured with nanoindentation. Fracture behaviour in transverse and longitudinal orientations is investigated experimentally and numerically. The results show that the Haversian canal (HC) size increases and the osteon wall thickness (OWT) decreases significantly in the aged group, whereas a nonsignificant difference is found in tissue properties. The crack initiation (J ic) and crack growth (J grow) toughness of the aged group are found to be significantly lower (p<0.01) than the young group in the transverse orientation; however, for the longitudinal orientation, only the value of J ic in the aged group is found significantly lower. Further, a 4-phase XFEM (based on micro-CT image) model is developed to investigate the crack propagation behaviour in both orientations. For the transverse orientation, results show that in the aged group, the crack initially follows the cementline and then penetrates the osteon, whereas, in the young group, it propagates along the cementline. These results are in agreement with experimental results where the decrease in J grow is more significant than the J ic in the aged group. This study suggests that ageing leads to a larger HC and reduced OWT, which weakens the crack deflection ability and causes fragility fracture. Further, the XFEM results indicate that the presence of a small microcrack in the vicinity of a major crack tip causes an increase in the critical stress intensity factor. [ABSTRACT FROM AUTHOR]

Details

Language :
English
ISSN :
13504533
Volume :
93
Database :
Academic Search Index
Journal :
Medical Engineering & Physics
Publication Type :
Academic Journal
Accession number :
150970004
Full Text :
https://doi.org/10.1016/j.medengphy.2021.05.021