Back to Search Start Over

Automated analysis of immediate reliability of T2 and T2* relaxation times of hip joint cartilage from 3 T MR examinations.

Authors :
Bugeja, Jessica M.
Chandra, Shekhar S.
Neubert, Aleš
Fripp, Jurgen
Lockard, Carly A.
Ho, Charles P.
Crozier, Stuart
Engstrom, Craig
Source :
Magnetic Resonance Imaging (0730725X). Oct2021, Vol. 82, p42-54. 13p.
Publication Year :
2021

Abstract

Magnetic resonance (MR) T2 and T2* mapping sequences allow in vivo quantification of biochemical characteristics within joint cartilage of relevance to clinical assessment of conditions such as hip osteoarthritis (OA). To evaluate an automated immediate reliability analysis of T2 and T2* mapping from MR examinations of hip joint cartilage using a bone and cartilage segmentation pipeline based around focused shape modelling. Technical validation. 17 asymptomatic volunteers (M: F 7:10, aged 22–47 years, mass 50–90 kg, height 163-189 cm) underwent unilateral hip joint MR examinations. Automated analysis of cartilage T2 and T2* data immediate reliability was evaluated in 9 subjects (M: F 4: 5) for each sequence. A 3 T MR system with a body matrix flex-coil was used to acquire images with the following sequences: T2 weighted 3D-trueFast Imaging with Steady-State Precession (water excitation; 10.18 ms repetition time (TR); 4.3 ms echo time (TE); Voxel Size (VS): 0.625 × 0.625 × 0.65 mm; 160 mm field of view (FOV); Flip Angle (FA): 30 degrees; Pixel Bandwidth (PB): 140 Hz/pixel); a multi-echo spin echo (MESE) T2 mapping sequence (TR/TE: 2080/18–90 ms (5 echoes); VS: 4 × 0.78 × 0.78 mm; FOV: 200 mm; FA: 180 degrees; PB: 230 Hz/pixel) and a MESE T2* mapping sequence (TR/TE: 873/3.82–19.1 ms (5 echoes); VS: 3 × 0.625 × 0.625 mm; FOV: 160 mm; FA: 25 degrees; PB: 250 Hz/pixel). Automated cartilage segmentation and quantitative analysis provided T2 and T2* data from test-retest MR examinations to assess immediate reliability. Coefficient of variation (CV) and intraclass correlations (ICC 2, 1) to analyse automated T2 and T2* mapping reliability focusing on the clinically important superior cartilage regions of the hip joint. Comparisons between test-retest T2 and (T2*) data revealed mean CV's of 3.385% (1.25%), mean ICC 2, 1 ′s of 0.871 (0.984) and median mean differences of −1.139 ms (+0.195 ms). The T2 and T2* times from automated analyses of hip cartilage from test-retest MR examinations had high (T2) and excellent (T2*) immediate reliability. • First automatic T2* mapping reliability study in the hip joint; and • First to be conducted on a commonly replaced weight bearing joint. • T2* data gave a 1.25% CV, 0.984 ICC 2, 1 and a median mean difference of +0.195 ms. • We present high reliability for T2 and T2* mapping from hip joint cartilages. • Reliability is essential for translation of T2* data to clinical applications. [ABSTRACT FROM AUTHOR]

Details

Language :
English
ISSN :
0730725X
Volume :
82
Database :
Academic Search Index
Journal :
Magnetic Resonance Imaging (0730725X)
Publication Type :
Academic Journal
Accession number :
151405082
Full Text :
https://doi.org/10.1016/j.mri.2021.06.008